3T4: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(6 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar
manufacturer=Tektronix |series=560-series scopes |type= 3T4 |
|manufacturer=Tektronix
summary=Programmable Sampling Sweep |
|series=560-series scopes
image=3t4 front.jpg |
|type=3T4
caption=3T4 sweep unit |
|summary=Programmable sampling sweep plug-in
designers= |
|image=Tek 3t4 front.jpeg
introduced=1965 |
|caption=3T4 Programable Sampling Sweep
discontinued=(?) |
|designers=
manuals=
|introduced=1965
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]] (PDF)
|discontinued=(?)
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (PDF, OCR)
|manuals=
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]]
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (OCR)
}}
}}
The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms.  It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].
The '''Tektronix 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms.  It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].
 
The [[283]] real-time adapter enables real-time sweeps with a 3T4.
 
{{MissingSpecs}}


==Specifications==
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.   
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.   
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.   
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.  maximum trigger frequency is 1 GHz.   
The maximum trigger frequency is 1 GHz.   


The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.   
The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.   
Line 27: Line 31:
* Single-display start
* Single-display start


==See Also==
==Links==
* [[012-0101-00]]
* See also [[012-0101-00]]
{{Documents|Link=3T4}}


==Pictures==
==Pictures==
<gallery>
<gallery>
File:3t4_front.jpg|front view
3t4_front.jpg | Front View
File:3t4_left.jpg|left view
3t4_left.jpg | Left View
File:3t4_right.jpg|right view
3t4_right.jpg | Right View
File:3t4_top.jpg|top view
3t4_top.jpg   | Top View
File:3t4_bottom.jpg|bottom view
3t4_bottom.jpg| Bottom View
File:Tek 3t4 1965 cat.jpg|Description in 1965 Tek Catalog
Tek 3t4 1965 cat.jpg | Description in 1965<br>Tektronix Catalog
File:Smpte apr1965 3t4.png|In April 1965 SMPTE Journal
Smpte apr1965 3t4.png | In April 1965 SMPTE Journal
</gallery>
</gallery>
==Components==
{{Parts|3T4}}


[[Category:560 series plugins]]
[[Category:560 series plugins]]

Latest revision as of 05:34, 29 November 2023

Tektronix 3T4
Programmable sampling sweep plug-in
3T4 Programable Sampling Sweep

Compatible with 560-series scopes

Produced from 1965 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.

The 283 real-time adapter enables real-time sweeps with a 3T4.

Key Specifications

  • please add

The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. maximum trigger frequency is 1 GHz.

The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.

The remotely programmable functions are

  • Equivalent-time sweep rate
  • Delay time
  • Samples per sweep
  • Normal or single-display mode
  • Single-display start

Links

Documents Referencing 3T4

Pictures

Components

Some Parts Used in the 3T4

Part Part Number(s) Class Description Used in
8056 154-0417-00 Vacuum Tube (Triode) low-voltage Nuvistor triode 422 502 W 1S1 3A7 3S3 3T4 5T3 10A1