3T6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(template, cat)
Line 1: Line 1:
The Tektronix Type 3T6 is a [[sampling_oscilloscope|sampling]]  
{{Plugin Sidebar 2 |
title=Tektronix 3T6 |
summary=Programmable Sampling Sweep |
image=3t6_front.JPG |
caption=3T6 sweep unit |
series=[[560-series scopes]] |
introduced=1969 |
discontinued=(?) |
manuals=
* http://bama.edebris.com/manuals/tek/3t6/
}}
The '''Tektronix Type 3T6''' is a [[sampling_oscilloscope|sampling]]  
plug-in for [[560-series scopes]].  It is particularly suited,
plug-in for [[560-series scopes]].  It is particularly suited,
and programmable, when used in a [[568]].   
and programmable, when used in a [[568]].   
In addition to the usual two 560-series connectors on the rear of the plug-in,  
In addition to the usual two 560-series connectors on the rear of the plug-in,  
the 3T6 has two extra connectors, J24 and P23.
the 3T6 has two extra connectors, J24 and P23.   J24 is used for programming the 3T6.   
J24 is used for programming the 3T6.   
P23 is a coaxial feed of the trigger input signal.   
P23 is a coaxial feed of the trigger input signal.   
Both of these connectors mate with corresponding connectors in the 568.
Both of these connectors mate with corresponding connectors in the 568.
Line 15: Line 26:
on the front panel of the 3T6 or remotely, through the 568, via connector J24.   
on the front panel of the 3T6 or remotely, through the 568, via connector J24.   


* http://bama.edebris.com/manuals/tek/3t6/
==Specifications==
[[Category:Specifications needed]]
''please add''


==Pictures==
<gallery>
<gallery>
Image:3t6_front.JPG|front view
Image:3t6_front.JPG|front view
Line 24: Line 38:
Image:3t6_rear.JPG|rear view
Image:3t6_rear.JPG|rear view
</gallery>
</gallery>
[[Category:560 series plugins]]
[[Category:Sampling plugins]]

Revision as of 10:00, 20 August 2014

Template:Plugin Sidebar 2 The Tektronix Type 3T6 is a sampling plug-in for 560-series scopes. It is particularly suited, and programmable, when used in a 568.

In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23. J24 is used for programming the 3T6. P23 is a coaxial feed of the trigger input signal. Both of these connectors mate with corresponding connectors in the 568.

The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event. The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.

Specifications

please add

Pictures