465

From TekWiki
Revision as of 12:46, 7 August 2022 by Qfissler (talk | contribs) (465 Opt 7 photo)
Jump to navigation Jump to search
Tektronix 465
Portable 100 MHz dual-trace scope
Tektronix 465 front

Produced from 1972 to 1983

Manuals

465

465B

Modifications

History

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures
Note: The Tektronix 465M scope has its own page.

The Tektronix 465 is a portable 100 MHz dual-trace oscilloscope with dual time-bases, introduced in November 1972. It is all solid-state except for the CRT. The 465 was very popular and Tek made them for quite a few years. According to microfiche records, 37 variations of the 465 were produced.

There was no 465A but a 465B (int. 1980) with the same base specs but improved performance. The 475 is a 200 MHz sister model. See also 465M.

The optional DM44 multimeter attaches to the top of the instrument.

Bill Turner worked as a calibration technician for the 465 oscilloscope group.

Key Specifications

Bandwidth DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C
Risetime 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C
Input impedance 1 MΩ ±2% // 20 pF
 Input voltage max. 500 V DC (250 VDC when DC coupled) + Peak AC or 500 Vp-p AC at < 1 kHz
Trigger coupling DC, AC, LF Reject, HF Reject
Channel isolation 100:1 at 25 MHz
Z-Axis input DC to 50 MHz; 5 Vp-p signal causes noticeable modulation at normal intensity
Output signals CH1 Vertical, A & B +Gate
Calibrator ~1 kHz, 300 mV, square wave
CRT T4650 (154-0676-00/154-0676-05/154-0676-10) tube, P31 phosphor, 18.5 kV acceleration, 8 cm × 10 cm graticule
Power 110/115/120/220/230/240 VAC ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz; 75 W

Internals

The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to TD3A, and 155-0032-00 chips (their -01 grade) as trigger amplifiers.

Links

Common Problems

Pictures

465

465 Mod UC

465B


CRTs used in the 465

Page Part nos Description Designers Used in
154-0731-00 154-0731-00 CRT Telequipment D75 455 465 465B 468
154-0731-04 154-0731-04 CRT 465 465B
T4650 154-0676-00 154-0676-05 154-0676-10 154-0676-14 CRT Connie Wilson Gary Nelson 465 Telequipment D75 Telequipment D755


CRTs used in the 465B

Page Part nos Description Designers Used in
154-0731-00 154-0731-00 CRT Telequipment D75 455 465 465B 468
154-0731-04 154-0731-04 CRT 465 465B

Custom ICs used in the 465

Page Model Part nos Description Designers Used in
155-0032-00 M55 155-0032-00 155-0032-01 variable-gain transconductance amplifier Roy Hayes Einar Traa 335 464 465 465B 466 475 475A 475M 634 650 651 652 653 655 656 670 671 7A12 475 FG504 1440 1460 1480 1481 1482 1485
155-0049-00 M079G 155-0049-00 155-0049-01 155-0049-02 sweep control with lockout Bill DeVey 335 464 465 466 475 475A 475M 485 5B31 5B40 5B52 5B42 5B44 7B53A 7B80 7B85 7B87 7B92A 7B90P 7B10 7B15 SC502 7B42N AN/USM-281C 067-0657-00
155-0076-00 M94 155-0076-00 input protection and probe logic John Addis Wink Gross 465 485 7A29 7A29P 11A52 11A71 11A72 SCD1000
155-0077-00 155-0077-00 155-0077-00 155-0077-01 vertical output amplifier 335 464 465 466 7704A
155-0078-00 M084 155-0078-xx 155-0273-00 155-0274-00 broadband amplifier John Addis 464 465 466 468 475 475A 475M 485 7834 7844 7854 7904 R7903 R7912 7912AD 7912HB 7104 7A16A 7A16P 7A24 7A26 7A42 067-0587-01 067-0680-00 AM503 PG502 PG508 DC510 DC5010 FG5010
155-0115-00 155-0115-00 155-0115-00 vertical amplifier 335 464 465 465B 466 468

Custom ICs used in the 465B

Page Model Part nos Description Designers Used in
155-0032-00 M55 155-0032-00 155-0032-01 variable-gain transconductance amplifier Roy Hayes Einar Traa 335 464 465 465B 466 475 475A 475M 634 650 651 652 653 655 656 670 671 7A12 475 FG504 1440 1460 1480 1481 1482 1485
155-0115-00 155-0115-00 155-0115-00 vertical amplifier 335 464 465 465B 466 468