The Tektronix Type 50 is a vertical plug-in for 560-series scopes.
{{Plugin Sidebar
It is an AC amplifier with a frequency response of 15Hz to 200kHz.
|manufacturer=Tektronix
It provides a fixed 1mV/div sensitivity.  The only control is vertical
|series=560-series scopes
position.
|type=50
|summary=200 kHz amplifier plug-in
|image=Tek type 50 front.jpg
|caption=Tek Type 50 front
|introduced=1961
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-264.pdf|Tektronix Type 50 Manual]]
}}The '''Tektronix Type 50''' is a vertical plug-in for [[560-series scopes]].
It was [[introduced in 1961]].  
It is an AC amplifier with a frequency response of 15 Hz to 200 kHz.
It provides a fixed 1 mV/div sensitivity.  The only control is vertical position. 
When paired with a Type [[51]] sweep, the Type 50 is useful for measurements in the audio frequency range.


Manual needed.
The Type 50 has a pair of [[2N1631]] germanium PNP transistors driving an output stage comprising a differential pair of pentodes.
 
<gallery>
Tek type 50 front.jpg
Tek type 50 right.jpg
Tek type 50 left.jpg
Tek type 50.jpg
Tek type 50 schematic.png|Schematic
Tektronix type 50 1961 cat.png|From 1961 Catalog
</gallery>
 
 
[[Category:560 series plugins]]
[[Category:Introduced in 1961]]

Revision as of 06:42, 8 May 2023

Tektronix 50
200 kHz amplifier plug-in
Tek Type 50 front

Compatible with 560-series scopes

Produced from 1961 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type 50 is a vertical plug-in for 560-series scopes. It was introduced in 1961. It is an AC amplifier with a frequency response of 15 Hz to 200 kHz. It provides a fixed 1 mV/div sensitivity. The only control is vertical position. When paired with a Type 51 sweep, the Type 50 is useful for measurements in the audio frequency range.

The Type 50 has a pair of 2N1631 germanium PNP transistors driving an output stage comprising a differential pair of pentodes.