Revision as of 06:19, 13 June 2018
The plug-in interface of the 500-series scopes is a single 16-pin Amphenol connector.
Pin-out
Pin | Function | Comment |
---|---|---|
1 | +Signal | 100 mV/cm, bias +67.5 V ±2% |
2 | Ground | |
3 | −Signal | 100 mV/cm, bias +67.5 V ±2% |
4 | Int Trig GND | 544, 546, 547, 555 only |
5 | Int Trig in | 544, 546, 547, 555 only |
6 | n/c | |
7 | Slave Pulse out | 547 only |
8 | Multi-trace sync | Cathode; grounded by CA, M etc. in Alt Trace mode |
9 | −150 V | min. 3.8 mA, max. 60 mA |
10 | +100 V | min. 4.5 mA, max. 50 mA |
11 | +225 V | min. 16 mA, max. 75 mA |
12 | +350 V | min. 0 mA, max. 20 mA |
13 | 6.3 VAC | plug-in AC heater supply, max. 2.8 A |
14 | 6.3 VAC | return for pin 13 |
15 | +75 V | min./max. 150 mA for DC series heaters and LV supply |
16 | Multi-trace sync | Anode |
Pin group function legend
DC power AC and heater power Deflection and Trigger Signals Control Signals