514: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
Line 5: Line 5:
caption=Tektronix 514 front |
caption=Tektronix 514 front |
introduced=1949 |
introduced=1949 |
discontinued=(?) |
discontinued=1954  |
 
manuals=
manuals=
* [http://bama.edebris.com/download/tek/514d/Tek%20514D%20Series%20A%20Manual.pdf Tektronix 514D Manual (PDF)]
* [http://bama.edebris.com/download/tek/514d/Tek%20514D%20Series%20A%20Manual.pdf Tektronix 514D Manual (PDF)]
Line 27: Line 28:
The +225 V supply uses three [[5V4G]] rectifier tubes in parallel.
The +225 V supply uses three [[5V4G]] rectifier tubes in parallel.


A 514D model exists, which has a 24-section 250 ns lumped L-C [[delay line]].   
Throughout it's run, a 'D' variant was available (514D, with the 'D' being stamped in by hand) which has a 24-section 250 ns lumped L-C [[delay line]].   
There is also a 514AD.  ''(How does the 514AD differ from the 514D?)''
There was also an 'A' version (514-A & 514-AD respectively), which appears to have been available in 1954.  ''(How does the 514AD differ from the 514D?)''


It has no [[thermal cutoff]].
It has no [[thermal cutoff]].

Revision as of 14:36, 24 January 2016

{{{manufacturer}}} 
10 MHz Tube scope
Tektronix 514 front

Produced from 1949 to 1954

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 514 is a monolithic general-purpose oscilloscope introduced in 1949 or 1950.

It was designed by Tektronix engineers Bob Davis and Dick Rhiger.

Using a three-section distributed distributed amplifier, it provides frequency response from DC to 10MHz. Prior to the 514, customers had to choose between an instrument with 10 MHz bandwidth (the 511) or an instrument with DC response (the 512).

The 514 provides DC response and 10 MHz bandwidth. It weighs 60 pounds (27 kg) and consumes 360 W. The 514 uses a 5CPA CRT with a total accelerating voltage of 3000 V (-1.5kV on the CRT cathode and +1.5kV on the CRT anode) . The standard phosphor for a 514 was P1. The deflection sensitivity of the CRT is approximately 27 V/cm vertical and 32 V/cm horizontal.

The power supply is regulated based on a -140 V reference produced by a OD3 gas regulator tube. The +225 V supply uses three 5V4G rectifier tubes in parallel.

Throughout it's run, a 'D' variant was available (514D, with the 'D' being stamped in by hand) which has a 24-section 250 ns lumped L-C delay line. There was also an 'A' version (514-A & 514-AD respectively), which appears to have been available in 1954. (How does the 514AD differ from the 514D?)

It has no thermal cutoff.

Specifications

  • frequency response: DC to 10MHz
  • input impedance: 1 megohm in parallel with 30 pF
  • maximum DC vertical deflection sensitivity: 300mV/cm
  • maximum AC vertical deflection sensitivity: 30mV/cm
  • weight: 62 pounds
  • power consumption: 375 watts.

Pictures