The Tektronix 515 is a 15MHz single-trace all-tube oscilloscope [[introduced in 1955]].   
The Tektronix 515 is a 15 MHz single-trace all-tube oscilloscope [[introduced in 1955]].   
It does not use plug-ins.
It does not use plug-ins.
A rackmount version, the RM15 was also sold.   
 
There is also a 515A.   
A rackmount version, the RM15 was also sold.  There is also a 515A.   
The HV power supply uses tree [[5642]] rectifiers to produce +2325V for the CRT anode
 
and -1675V for the CRT cathode.  The LV power supply is linear, using a [[6080]] tube as
The HV power supply uses three [[5642]] rectifiers to produce +2325 V for the CRT anode
the pass tube of the series regulator for +300V and +100V supply.  The -150V supply is  
and -1675 V for the CRT cathode.  The LV power supply is linear, using a [[6080]] tube as
regulated by a [[6AU5]] tube.  The voltage reference for the -150V supply is a [[5651]]
the pass tube of the series regulator for +300 V and +100 V supply.  The -150 V supply is  
regulated by a [[6AU5]] tube.  The voltage reference for the -150 V supply is a [[5651]]
tube.  The 515 and 515A use [[selenium rectifiers]].  A kit was later made available
tube.  The 515 and 515A use [[selenium rectifiers]].  A kit was later made available
for converting them to silicon rectifiers for improved reliability.   
for converting them to silicon rectifiers for improved reliability.   


The vertical amplifier is fully differential, DC-coupled, and all tube.  The
The vertical amplifier is fully differential, DC-coupled, and all tube.  The stages are as follows:
stages are as follows:


* input buffer, cathode followers, [[6AU6]]
* input buffer, cathode followers, [[6AU6]]
Line 25: Line 25:


The 515A has a Z-axis input and slightly higher vertical sensitivity than the 515.
The 515A has a Z-axis input and slightly higher vertical sensitivity than the 515.
The maximum vertical sensitivity is 100mV/div for the 515 and 50mV for the 515A.
The maximum vertical sensitivity is 100 mV/div for the 515 and 50mV for the 515A.
The [[516]] is essentially a dual-trace version of the 515.
The [[516]] is essentially a dual-trace version of the 515.


The 515 and 515A use the [[T55|T55 CRT CRT]].
The 515 and 515A use the [[T55|T55 CRT CRT]]. P31 [[phosphor]] was standard.
P31 [[phosphor]] was standard.


Serial numbers 101 through 1000 are "Type 515".   
Serial numbers 101 through 1000 are "Type 515".   
Line 53: Line 52:
File:Tek rm15.jpg
File:Tek rm15.jpg
</gallery>
</gallery>
[[Category:Tube scopes]]

Revision as of 11:25, 9 May 2014

The Tektronix 515 is a 15 MHz single-trace all-tube oscilloscope introduced in 1955. It does not use plug-ins.

A rackmount version, the RM15 was also sold. There is also a 515A.

The HV power supply uses three 5642 rectifiers to produce +2325 V for the CRT anode and -1675 V for the CRT cathode. The LV power supply is linear, using a 6080 tube as the pass tube of the series regulator for +300 V and +100 V supply. The -150 V supply is regulated by a 6AU5 tube. The voltage reference for the -150 V supply is a 5651 tube. The 515 and 515A use selenium rectifiers. A kit was later made available for converting them to silicon rectifiers for improved reliability.

The vertical amplifier is fully differential, DC-coupled, and all tube. The stages are as follows:

  • input buffer, cathode followers, 6AU6
  • first gain stage, differential amplifier, T-coil, 12BY7
  • unity gain buffer, cathode follower, 6DJ8
  • output amplifier, differential amplifier, T-coil, 6CL6

The horizontal amplifier uses half of a 6DJ8 as a buffer, followed by a 6DJ8 as a differential amplifier and phase splitter, followed by the two halves of another 6DJ8 as the output cathode followers driving the horizontal CRT deflection plates.

The trigger is a 6DJ8 differential trigger amplifier followed by a 6DJ8 Schmitt trigger.

The 515A has a Z-axis input and slightly higher vertical sensitivity than the 515. The maximum vertical sensitivity is 100 mV/div for the 515 and 50mV for the 515A. The 516 is essentially a dual-trace version of the 515.

The 515 and 515A use the T55 CRT CRT. P31 phosphor was standard.

Serial numbers 101 through 1000 are "Type 515". Starting with serial number 1001, they are "Type 515A".