* Pin 8: +180V, unregulated
* Pin 8: +180V, unregulated


The 517 makes extensive use of the [[distributed amplifier]] concept.  The vertical signal path is
The 517 makes extensive use of the [[distributed amplifier]] concept.   
as follows:
It was originally designed to use the 5XP CRT,
which has 38V/cm vertical deflection sensitivity when operated with 24kV acceleration voltage.
The vertical sensitivity at the input connector is 0.1V/cm.  So the voltage gain is 380.
For 4cm deflection, a 152-volt differential output swing is required.
The vertical signal path is as follows:


* Gain Stage 1: single-ended, six sections, distributed, [[6AK5]] pentodes
* Gain Stage 1: single-ended, six sections, distributed, [[6AK5]] pentodes
Line 47: Line 51:
other Tek scopes which use HV oscillators in the ultrasonic range.
other Tek scopes which use HV oscillators in the ultrasonic range.
   
   
The power consumption of a 517 is 1250 Watts.  The indicator unit weighs 76 pounds and the external
power supply weighs 72 pounds. 