{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar
title=Tektronix 531|
|manufacturer=Tektronix
summary=10 MHz scope |
|series=5000-series scopes
image=Tek 531a g front.jpg |
|model=531
caption=Tektronix 531 |
|summary=10 MHz oscilloscope
introduced=1954 |
|image=Tek 531a g front.jpg
discontinued=1973 |
|caption=Tektronix 531
manuals=
|introduced=1954
* [http://bama.edebris.com/download/tek/531_541/531_541.djvu Tektronix 531/541 Manual (DjVu)]
|discontinued=1973
* [http://w140.com/mmm/tek-531-541.pdf Tektronix 531/541 Manual (PDF)]
|designers=Dick Rhiger
* [http://w140.com/tek_fcp/tek_type_531_factory_cal_proc.pdf Tektronix 531 Factory Calibration Procedure (PDF)]
|manuals=
* [http://w140.com/tek_fcp/tek_type_531a_factory_cal_proc.pdf Tektronix 531A Factory Calibration Procedure (PDF)]
'''531'''
* [[Media:070-203.pdf|Tektronix 531/541 Manual]] (OCR)
* [[Media:tek_531_fcp.pdf|531 Factory Calibration Procedure]] (OCR)


* [[Media:tek_531_fcp.pdf|Tektronix 531 Factory Calibration Procedure (PDF, OCR)]]
'''531A'''
* [[Media:tek_531a_fcp.pdf|Tektronix 531A Factory Calibration Procedure (PDF, OCR)]]
* [[Media:070-301.pdf|Tektronix RM31A Manual]]
* [[Media:Tek 531a fcp feb 1968.pdf]]
* [[Media:tek_531a_fcp.pdf|531A Factory Calibration Procedure]] (OCR)
* [[Media:Tek 531a fcp feb 1968.pdf|531A Factory Calibration Procedure, February 1968]]
* [[Media:Tek 531a mods.pdf|Tektronix 531A Modifications]]
}}
}}
The '''Tektronix Type 531''' is a 10 MHz oscilloscope that accepts [[letter-series and 1-series plug-ins]].
The '''Tektronix Type 531''' is a 10 MHz oscilloscope that accepts [[letter-series and 1-series plug-ins]].
It is exactly like Type [[535]] except it does not have the Delayed Sweep (dual timebase) feature.
It is exactly like Type [[535]] except it does not have the Delayed Sweep (dual timebase) feature.
Line 25: Line 28:
which has more convenient controls and a slightly faster (15 MHz) vertical amplifier.
which has more convenient controls and a slightly faster (15 MHz) vertical amplifier.


531s with below S/N 7950 have DuMont [[154-081|5BGP2]] instead of Tektronix [[T5330|T533P2]].
In serial numbers 101 to 7600, the 531's L-C [[delay line]] is in the middle of the vertical amplifier.   
 
In serial numbers 101 to 7600, the 531's L-C [[delay line]] is before the vertical amplifier.   
In serial numbers 7601 and up, the 531's delay line is between the vertical amplifier and the CRT.
In serial numbers 7601 and up, the 531's delay line is between the vertical amplifier and the CRT.
This change was the result of [[John Kobbe]]'s insight that if the far end of the delay line was an open circuit (which the CRT approximates),
This change was the result of [[John Kobbe]]'s insight that if the far end of the delay line was an open circuit (which the CRT approximates),
the reflected wave could be absorbed at the source end.
the reflected wave could be absorbed at the source end.
This "single termination" approach made it possible to do away with the output chassis.
This "single termination" approach made it possible to do away with the input chassis.
All Tek scopes using a lumped-constant delay line went to this topology.
All subsequent Tek scopes with a lumped-constant delay line used this topology.


There is also a rack-mount version, Types RM31 and RM31A.
There is also a rack-mount version, Types RM31 and RM31A.
Line 40: Line 41:
The [[541]] is mostly the same as the 531, but has a [[distributed amplifier|distributed vertical amplifier]]  
The [[541]] is mostly the same as the 531, but has a [[distributed amplifier|distributed vertical amplifier]]  
for 30 MHz bandwidth, and a different CRT.
for 30 MHz bandwidth, and a different CRT.


{{BeginSpecs}}
{{BeginSpecs}}
Line 56: Line 55:
{{Spec | Cooling  | AC Fan }}
{{Spec | Cooling  | AC Fan }}
{{Spec | Trigger Modes | AC/DC/AC LF Reject, and HF Sync}}
{{Spec | Trigger Modes | AC/DC/AC LF Reject, and HF Sync}}
{{Spec | Anode Potential | 10 kV}}
{{Spec | Anode Potential | 10 kV (relative to cathode)}}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Weight| 61,5 lbs / 27,8 kg }}
{{Spec | Weight| 61,5 lbs / 27,8 kg }}
{{EndSpecs}}
{{EndSpecs}}


==Links==
{{Documents|Link=531}}
{{Documents|Link=531A}}


==Pictures of  531==
==Pictures==
===531===
<gallery>
<gallery>
531_early_1.jpg        | early 531 with [[C|Type 53C]]
531_early_1.jpg        | early 531 with [[C|Type 53C]]
Tek 531 brown 1.jpg | Brown-era 531 with [[CA|Type CA]]
Tek 531 brown 1.jpg     | Brown-era 531 with [[CA|Type CA]]
Tek 531 brown 2.jpg | Brown-era 531 with [[CA|Type CA]]
Tek 531 brown 2.jpg     | Brown-era 531 with [[CA|Type CA]]
Tek 531 brown 3.jpg | Brown-era 531 Rear
Tek 531 brown 3.jpg     | Brown-era 531 Rear
</gallery>
</gallery>


==Pictures of  531A==
===531A===
<gallery>
<gallery>
Tek 531a g front.jpg
Tek 531a g front.jpg
Tek 531a trace.jpg
Tek 531a on cart.JPG    | 531A on [[202]] cart
Tek 531a on cart.JPG    | 531A on [[202]] cart
Tek 531a on cart.jpg    | 531A on [[500]]/[[53]]cart
Tek 531a on cart.jpg    | 531A on [[500]]/[[53]]cart
Line 88: Line 91:
</gallery>
</gallery>


==Pictures of  RM31A==
===RM31A===
<gallery>
<gallery>
rm31a.jpg              | RM31A
rm31a.jpg              | RM31A
</gallery>
</gallery>
==Components==
{{Parts|531}}
{{Parts|531A}}
{{Parts|RM31A}}
[[Category:500 series scopes]]