31,818
edits
No edit summary |
No edit summary |
||
(14 intermediate revisions by 4 users not shown) | |||
Line 7: | Line 7: | ||
discontinued=1974 | | discontinued=1974 | | ||
manuals= | manuals= | ||
* [[Media:070-0508-00.pdf|549 Instruction]] (PDF) | * [[Media:070-0508-00.pdf|549 Instruction]] (OCR PDF, 22M) | ||
* [http://w140.com/mmm/tek-549.pdf | * [http://w140.com/mmm/tek-549.pdf 549 Instruction (PDF, 162M)] | ||
* [http://bama.edebris.com/manuals/tek/549 549 | * [http://bama.edebris.com/manuals/tek/549 549 Instruction @ BAMA (PDF, 27M)] | ||
====Maintenance Notes==== | ====Maintenance Notes==== | ||
Line 47: | Line 47: | ||
to have linear phase response over this same frequency range. | to have linear phase response over this same frequency range. | ||
In the 549, this buffer is implemented | In the 549, this buffer is implemented with a [[6DJ8]] cathode follower at the plug-in interface | ||
cathode follower | driving an NPN BJT differential amplifier at the bottom of a cascode with a [[7119]] tube on top. | ||
The output of the cascode (the plate of the 7119) drives the [[delay line]]. | The output of the cascode (the plate of the 7119) drives the [[delay line]]. | ||
Line 82: | Line 80: | ||
Line input is connected to main transformer primary via two switches, one inside the chassis to select the 110 V or 230 V range, and another on the rear of the chassis to select Low/Medium/High voltage in either range. | Line input is connected to main transformer primary via two switches, one inside the chassis to select the 110 V or 230 V range, and another on the rear of the chassis to select Low/Medium/High voltage in either range. | ||
Multiple secondary windings feeds diodes for rectification for different voltages. Both center-tap and bridge configuration is used. | Multiple secondary windings feeds diodes for rectification for different voltages. Both center-tap and bridge configuration is used. Transistors and/or tubes are used for regulation. | ||
Transistors and/or tubes are used for regulation. | |||
As is common in many Tektronix scopes, all regulated voltages are referred to the negative regulated rail (−150 V in this case) by fixed low-tolerance dividers. Only the −150 V voltage is trimmed, its reference is a [[5651]] VR tube. A [[12AX7]] is used as the comparator, three [[12B4]] in parallel are used as series pass tubes. A [[6AU6]] is used as an error amplifier. | As is common in many Tektronix scopes, all regulated voltages are referred to the negative regulated rail (−150 V in this case) by fixed low-tolerance dividers. Only the −150 V voltage is trimmed, its reference is a [[5651]] VR tube. A [[12AX7]] is used as the comparator, three [[12B4]] in parallel are used as series pass tubes. A [[6AU6]] is used as an error amplifier. | ||
Line 95: | Line 92: | ||
The 549 has a 65°C (150°F) [[thermal cutoff]]. | The 549 has a 65°C (150°F) [[thermal cutoff]]. | ||
The 549 uses a [[120-0423-00]] HV transformer | The 549 uses a [[120-0423-00]] HV transformer driven by a [[6GF5]] tube from +470 V. | ||
==Links== | ==Links== | ||
* [https://lazyelectrons.wordpress.com/2018/01/11/tektronix-549-restoration/ Rajesh's Tek 549 Restoration] | * [https://lazyelectrons.wordpress.com/2018/01/11/tektronix-549-restoration/ Rajesh's Tek 549 Restoration] / [https://www.youtube.com/watch?v=8rWH-uuf60U Video] | ||
* [http://www.radiomuseum.org/forum/tektronix_the_storage_story.html Tektronix, the Storage Story] (1966) @ radiomuseum.org | * [http://www.radiomuseum.org/forum/tektronix_the_storage_story.html Tektronix, the Storage Story] (1966) @ radiomuseum.org | ||
* A [https://www.youtube.com/watch?v=1SRtm7eva0A 549 @ YouTube] | * A [https://www.youtube.com/watch?v=1SRtm7eva0A 549 @ YouTube] | ||
Line 119: | Line 103: | ||
Tek-549 and d.jpg | 549 front, earlier round bezel | Tek-549 and d.jpg | 549 front, earlier round bezel | ||
Tek 549 mt1.jpg | 549 front, later rectangular bezel | Tek 549 mt1.jpg | 549 front, later rectangular bezel | ||
Tek 549 trace2.jpg | | Tek 549 trace2.jpg | | ||
Tek_549-Front.jpeg | | |||
Tek_549-Stroage-Ctrl.jpeg | 549 Storage controls | |||
Tek 549 trace2..jpg | | Tek 549 trace2..jpg | | ||
Tek 549 trace.jpg | | Tek 549 trace.jpg | | ||
Line 128: | Line 114: | ||
Tek 549 1a4 1.jpg | | Tek 549 1a4 1.jpg | | ||
Tek 549 1a4 2.jpg | | Tek 549 1a4 2.jpg | | ||
Tek_549-Rear.jpeg | 549 Rear | |||
Tek_549-Line-Range.jpeg | Line voltage selector | |||
Tek 549 1a4 3.jpg | | Tek 549 1a4 3.jpg | | ||
Tek 549 1a4 4.jpg | | Tek 549 1a4 4.jpg | | ||
549_Delayed_Trace.jpg | B INTEN BY A Trig in 549 | 549_Delayed_Trace.jpg | B INTEN BY A Trig in 549 | ||
549_Dual_Trace.jpg | Dual trace display in 549 | 549_Dual_Trace.jpg | Dual trace display in 549 | ||
Tek 549-1 knob layout.jpg|549 knob layout | |||
</gallery> | </gallery> | ||
Line 144: | Line 133: | ||
===Internal=== | ===Internal=== | ||
<gallery> | <gallery> | ||
Tek_549-LHS.jpeg | LHS | |||
Tek_549-RHS.jpeg | RHS | |||
Tek_549-RHS-Timebase.jpeg | RHS Timebase Ch: Door Open | |||
Tek_549-Top.jpeg | Top | |||
Tek_549-Under.jpeg | Underside | |||
Tek_549-V-Amp.jpeg | 8608 vertical output tubes | |||
549_vert_amp.jpg | Vertical amp | 549_vert_amp.jpg | Vertical amp | ||
549_Vertical_OP.jpg | 8608 vertical output tubes | 549_Vertical_OP.jpg | 8608 vertical output tubes | ||
Tek 549 vertamp on.jpg | 8608 vertical output tubes | Tek 549 vertamp on.jpg | 8608 vertical output tubes | ||
549 v out.jpg | |||
549_top.jpg | Top view | 549_top.jpg | Top view | ||
549_storage_board.jpg | Storage board | 549_storage_board.jpg | Storage board | ||
Line 153: | Line 149: | ||
Wellenkino 549-7.jpg | | Wellenkino 549-7.jpg | | ||
Wellenkino 549-6.jpg | | Wellenkino 549-6.jpg | | ||
Tek_549-Prim-Sel-Sw.jpeg | Primary voltage range selector | |||
549_Tubes_ON1.jpg | LV power supply tubes | 549_Tubes_ON1.jpg | LV power supply tubes | ||
549_Tubes_ON.jpg | LV power supply tubes | 549_Tubes_ON.jpg | LV power supply tubes | ||
Line 163: | Line 160: | ||
[[Category:Introduced in 1966]] | [[Category:Introduced in 1966]] | ||
[[Category:Analog storage scopes]] | [[Category:Analog storage scopes]] | ||