549: Difference between revisions

46 bytes added ,  30 July 2018
mNo edit summary
Line 86: Line 86:
The 549 power supply uses a [[delay relay|6N030 delay relay (P/N 148-0021-00)]] to control a relay that switches supply voltages on only after the tubes are warmed up. On power up, only heater voltage is applied to the tubes.  After a delay of up to 60 seconds, the thermal delay relay activates the main relay (driven from unregulated +170 V). This also cuts out the delay relay, which can cool down and will be ready to delay again even after a quick interrupt in power input.
The 549 power supply uses a [[delay relay|6N030 delay relay (P/N 148-0021-00)]] to control a relay that switches supply voltages on only after the tubes are warmed up. On power up, only heater voltage is applied to the tubes.  After a delay of up to 60 seconds, the thermal delay relay activates the main relay (driven from unregulated +170 V). This also cuts out the delay relay, which can cool down and will be ready to delay again even after a quick interrupt in power input.


The 549 has a 65°C/150°F [[thermal cutoff]].
The 549 has a 65°C/150°F [[thermal cutoff]].
 
The 549 uses a [[120-0423-00]] HV transformer.


==Links==
==Links==