The Tektronix 556 is a [[dual-beam scopes|dual-beam scope]], the successor to the Tektronix [[555]]. It uses [[letter-series and 1-series plug-ins]]. A rack-mount version, the RM556 also exists.
The Tektronix 556 is a [[dual-beam scopes|dual-beam scope]], the successor to the Tektronix [[555]]. It uses [[letter-series and 1-series plug-ins]]. A rack-mount version, the RM556 also exists. The 556, which is wider than the average 500-series scope, fits in the [[205]] cart.


== Dual-Beam Modes ==
== Dual-Beam Modes ==
Line 19: Line 19:
the removable timing units in the 555.  The 556 takes  
the removable timing units in the 555.  The 556 takes  
two [[letter-series and 1-series plug-ins|letter-series or 1-series vertical plug-ins]].
two [[letter-series and 1-series plug-ins|letter-series or 1-series vertical plug-ins]].
The bandwidth is 50MHz.
The 556's bandwidth is 50MHz, whereas the 555's is 30.


== Comparison with the 565 ==
== Comparison with the 565 ==
Line 26: Line 26:
[[2-series or 3-series vertical plug-ins]]  
[[2-series or 3-series vertical plug-ins]]  
and has much lower vertical and trigger bandwidth.
and has much lower vertical and trigger bandwidth.
The 556, which is wider than the average 500-series scope, fits in the [[205]] cart.


* [http://bama.edebris.com/download/tek/556/tek%20556.pdf Tektronix 556 Manual (PDF)]
* [http://bama.edebris.com/download/tek/556/tek%20556.pdf Tektronix 556 Manual (PDF)]

Revision as of 10:10, 19 April 2014

The Tektronix 556 is a dual-beam scope, the successor to the Tektronix 555. It uses letter-series and 1-series plug-ins. A rack-mount version, the RM556 also exists. The 556, which is wider than the average 500-series scope, fits in the 205 cart.

Dual-Beam Modes

The 556 is a true dual-beam scope and none of the signal path is shared between the two beams. Electrically speaking, the power supply and the calibrator are the only parts that are common to both beams. The 556 has almost complete left-right symmetry, corresponding to upper and lower beams. Although the beams can be operated completely independently, the 556 provides many options for routing signals between the vertical plug-ins, triggers, sweeps, horizontal and vertical amplifiers. For example, a common use for a 556 is to view two simultaneous single-shot events, both sweeps being triggered by one of the traces. For this purpose, the 556 allows the output of one sweep generator to be routed to the horizontal amplifier of the other beam, so it drives both beams. Many other more sophisticated modes are also available.

Triggering

The triggering in the 556 is done using tunnel diodes and the trigger circuit sits on its own small PC board just behind the trigger source selection switch.

Vertical Amplifiers

The vertical amplifier of the 556 is solid state except for the input cathode followers (12AT7) and and the output stage (8608).

Comparison with the 555

The 556 is a one-piece unit whereas the 555 has a the power supply in a separate box. Triggering and sweep circuitry is integrated into the 556 mainframe, as opposed to the removable timing units in the 555. The 556 takes two letter-series or 1-series vertical plug-ins. The 556's bandwidth is 50MHz, whereas the 555's is 30.

Comparison with the 565

The 556 superficially resembles the 565, which is is also a dual-beam one-piece scope, but the 565 takes two 2-series or 3-series vertical plug-ins and has much lower vertical and trigger bandwidth.