The Tektronix Type 560 is a 1MHz oscilloscope that uses 560-series plug-ins.
{{Oscilloscope Sidebar |manufacturer=Tektronix |designers= |series=560-series scopes|
Later 560-series scopes were made with more powerful power supplies than the 560.
model= 560 |
Plug-ins that use a lot of power are not compatible with the 560.
summary=1 MHz scope |
image=Tek 560 trace2.jpg |
caption=Tektronix 560 front |
introduced=1961 |
discontinued=1962 |
manuals=
* [[Media:070-268.pdf|Tektronix 560 Manual]] (PDF, OCR)
* [https://w140.com/tek_560_560_product_release.pdf Tektronix 560 and 561 Product Release] (PDF)
* [[Media:Tek field maintenance support 560 cap std.pdf|Tektronix 560 Series Capacity Standard]] (PDF, needs OCR)
* [[Media:Tek 560 fcp.pdf|Tektronix 560 Factory Calibration Procedure]] (PDF, needs OCR)
}}
The '''Tektronix 560''' is a scope [[introduced in 1961]] which uses 50 and 60 series plug-ins for both the vertical and horizontal deflection.


Manual needed.
It is the first of the [[560-series scopes]], which contain no amplifier stages, requiring the plug-ins to directly drive the CRT deflection plates. 
While promoted by Tek as having the advantage of ''“not limited by additional circuitry between the plug-in and the deflection plates”'',
this configuration has the significant disadvantage that gain or sweep need to be calibrated individually each time
a plug-in is swapped to even get crude accuracy, as the raw deflection factor of the CRT varies to a relatively large
degree between units, and the mainframe has no circuitry to normalize this difference.


Photos needed.
In scopes that have amplifiers in the mainframe, this step can be skipped, as doing so only tunes the accuracy to a small amount of additional precision.
 
It may be for this reason that Tektronix referred to the 560 series mainframes as “indicators” rather than oscilloscopes.
 
The 560 was introduced along with the similar [[561]] in 1961.  A rack model was never offered. 
Both of the mainframes use conventional 5” round CRTs with glass envelopes. 
 
The 561 also supports the 70 series plug-ins which are not compatible with the 560. 
Certain members of the 70 series vertical amplifiers give a system bandwidth of 4 MHz in the 561. 
The later 2- and 3- series plug-ins cannot be used in the 560 or 561, as they consume more power.
 
The 560 and 561 were short-lived. Both were replaced by the [[561A]], which offered several performance improvements, within less than a year.
 
{{MissingSpecs}}
 
The maximum system bandwidth of the 560 is 1 MHz. 
 
==Internals==
 
The 560 uses a [[T5030]] CRT, referred to as a "T503P2" (P2 [[phosphor]]) in the manual. 
The CRT has -3,300 V on the cathode and +175 V on the [[aquadag]].
 
The only circuit in the 560 apart from the CRT circuits and power supply is a voltage/timing calibrator. 
 
===Power Supply===
The 560 has a power supply that is similar to the [[503]]'s power supply.
Mains power first passes through transformer T601,
which produces unregulated AC heater current and 170 V<sub>RMS</sub> for the second part of the power supply. 
 
The second part is a regulated Armstrong power oscillator operating at 25 kHz, using transformer T620 and a V620, a [[6DQ5]].
The secondary outputs of T620 are simply rectified and filtered, producing -12 V, +125 V, -100 V, and -3,400 V.
All regulation is performed by controlling the screen grid voltage on V620, the power oscillator tube.
 
In principle, the design used in the 560, which resembles a modern SMPS supply, like that in a [[7704]], can offer higher efficiency
and lower tube count compared to the power supply of the [[561]], which uses a traditional design more similar to a [[545]].
 
The increased efficiency comes from the elimination of series regulator tubes, which typically operate with around 100 V across them. 
The tube count reduction comes from eliminating the pass tube and the error amplifier for each regulated voltage that the power supply produces. 
Additional efficiency is gained by the 560's power supply because it doesn't need to supply heater current to all of those tubes.
 
The 560 provides a maximum total of 25 watts of DC power to the plug-ins, less than other 560-series mainframes.
Plug-ins whose model number starts with a 3 (e.g., the [[3A6]]) are not electrically compatible with the 560 because their power draw
exceeds what the 560 can provide.
 
==Pictures==
 
<gallery>
Tek 560 front.jpg|560 with [[50|Type 50]] and [[51|Type 51]] plug-ins
Tek 560 left internal.jpg
Tek 560 right internal.jpg
Tek 560 trace1.jpg
Tek 560.jpg|Description in 1962 Catalog
Tek 560 1.jpeg
Tek 560 2.jpeg
Tek 560 3.jpeg
Tek 560 4.jpeg
Tek 560 5.jpeg
Tek 560 power oscillator.jpg
Tek 560 ps.png|Power Supply Schematic
</gallery>
 
{{Parts|560}}
 
[[Category:560 series scopes]]

Revision as of 16:32, 10 October 2021

Tektronix 560
1 MHz scope
Tektronix 560 front

Produced from 1961 to 1962

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 560 is a scope introduced in 1961 which uses 50 and 60 series plug-ins for both the vertical and horizontal deflection.

It is the first of the 560-series scopes, which contain no amplifier stages, requiring the plug-ins to directly drive the CRT deflection plates. While promoted by Tek as having the advantage of “not limited by additional circuitry between the plug-in and the deflection plates”, this configuration has the significant disadvantage that gain or sweep need to be calibrated individually each time a plug-in is swapped to even get crude accuracy, as the raw deflection factor of the CRT varies to a relatively large degree between units, and the mainframe has no circuitry to normalize this difference.

In scopes that have amplifiers in the mainframe, this step can be skipped, as doing so only tunes the accuracy to a small amount of additional precision.

It may be for this reason that Tektronix referred to the 560 series mainframes as “indicators” rather than oscilloscopes.

The 560 was introduced along with the similar 561 in 1961. A rack model was never offered. Both of the mainframes use conventional 5” round CRTs with glass envelopes.

The 561 also supports the 70 series plug-ins which are not compatible with the 560. Certain members of the 70 series vertical amplifiers give a system bandwidth of 4 MHz in the 561. The later 2- and 3- series plug-ins cannot be used in the 560 or 561, as they consume more power.

The 560 and 561 were short-lived. Both were replaced by the 561A, which offered several performance improvements, within less than a year.

Key Specifications

  • please add

The maximum system bandwidth of the 560 is 1 MHz.

Internals

The 560 uses a T5030 CRT, referred to as a "T503P2" (P2 phosphor) in the manual. The CRT has -3,300 V on the cathode and +175 V on the aquadag.

The only circuit in the 560 apart from the CRT circuits and power supply is a voltage/timing calibrator.

Power Supply

The 560 has a power supply that is similar to the 503's power supply. Mains power first passes through transformer T601, which produces unregulated AC heater current and 170 VRMS for the second part of the power supply.

The second part is a regulated Armstrong power oscillator operating at 25 kHz, using transformer T620 and a V620, a 6DQ5. The secondary outputs of T620 are simply rectified and filtered, producing -12 V, +125 V, -100 V, and -3,400 V. All regulation is performed by controlling the screen grid voltage on V620, the power oscillator tube.

In principle, the design used in the 560, which resembles a modern SMPS supply, like that in a 7704, can offer higher efficiency and lower tube count compared to the power supply of the 561, which uses a traditional design more similar to a 545.

The increased efficiency comes from the elimination of series regulator tubes, which typically operate with around 100 V across them. The tube count reduction comes from eliminating the pass tube and the error amplifier for each regulated voltage that the power supply produces. Additional efficiency is gained by the 560's power supply because it doesn't need to supply heater current to all of those tubes.

The 560 provides a maximum total of 25 watts of DC power to the plug-ins, less than other 560-series mainframes. Plug-ins whose model number starts with a 3 (e.g., the 3A6) are not electrically compatible with the 560 because their power draw exceeds what the 560 can provide.

Pictures


Some Parts Used in the 560

Part Part Number(s) Class Description Used in
0G3 154-0291-00 Gas Discharge Tube (Voltage regulator) 85 V voltage reference 132 506 547 560 561 561A 561S 564 565 567 661 TU-4 Z
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
6DQ5 154-0317-00 Vacuum Tube (Pentode) beam power pentode 560
6GE8 154-0260-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 125 132 560
T5030 154-0264-00 154-0265-00 154-0266-00 154-0267-00 154-0341-00 CRT CRT 503 504 560 561 661