570: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
[[File:Tektronix-570-Outside-Front.jpg|thumb|350px|right]]
{{Oscilloscope Sidebar|
The '''Tektronix 570''' is a curve tracer for tubes.
title=Tektronix 570 |
It was introduced in 1955.
image=Tektronix-570-Outside-Front.jpg |
caption=Tektronix 570 front |
introduced=1955 |
discontinued=(?) |
summary=Curve tracer for tubes |
manuals=
* [http://w140.com/tek_570_rk.pdf Tektronix 570 Manual 070-167 (good quality, OCR, PDF)]
* [http://w140.com/tek_570_manual_070-359_7-63.pdf Tektronix 570 Manual (good quality, PDF)]
* [http://w140.com/mmm/tek-570.pdf Tektronix 570 Manual (mediocre quality, PDF)]
* [http://w140.com/tek_fcp/tek_570_fac_cal.pdf Tektronix 570 Factory Calibration Procedure (PDF)]
}}
The '''Tektronix 570''' is a curve tracer for tubes, introduced in 1955.
It sweeps the plate voltage between zero and a selectable maximum voltage
It sweeps the plate voltage between zero and a selectable maximum voltage
while "stepping" the control grid through a set of voltages.   
while "stepping" the control grid through a set of voltages.   


A selectable screen voltage is available for testing tubes with screens.  The plate voltage is measured and applied
A selectable screen voltage is available for testing tubes with screens.   
to the X-axis of the display.  The plate current is measured and amplified and
The plate voltage is measured and applied to the X-axis of the display.   
is applied to the Y-axis of the display.   
Plate current is measured and amplified and is applied to the Y-axis of the display.   
 
{{MissingSpecs}}
 
==Internals==


The 570 contains five transformers:
The 570 contains five transformers:
Line 23: Line 38:
The second stage is a differential amplifier made of both halves of a [[6BQ7A]].
The second stage is a differential amplifier made of both halves of a [[6BQ7A]].


* [http://w140.com/tek_570_rk.pdf Tektronix 570 Manual 070-167 (good quality, OCR, PDF)]
==Pictures==
* [http://w140.com/tek_570_manual_070-359_7-63.pdf Tektronix 570 Manual (good quality, PDF)]
* [http://w140.com/mmm/tek-570.pdf Tektronix 570 Manual (mediocre quality, PDF)]
* [http://w140.com/tek_fcp/tek_570_fac_cal.pdf Tektronix 570 Factory Calibration Procedure (PDF)]


<gallery>
<gallery>

Revision as of 03:52, 1 November 2016

{{{manufacturer}}} 
Curve tracer for tubes
Tektronix 570 front

Produced from 1955 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 570 is a curve tracer for tubes, introduced in 1955. It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.

A selectable screen voltage is available for testing tubes with screens. The plate voltage is measured and applied to the X-axis of the display. Plate current is measured and amplified and is applied to the Y-axis of the display.

Key Specifications

  • please add

Internals

The 570 contains five transformers:

  • T310: center-tapped isolation transformer for plate sweep
  • T340: multitap transformer for heater voltages
  • T401: multitap autotransformer for selecting peak plate voltage, feeds T310
  • T501: transformer for floating supplies and screen voltage supply
  • T620: transformer for 60kHz HV power oscillator for CRT voltages

The screen supply is regulated and uses a 6CD6GA tube as the series regulator.

The vertical and horizontal amplifiers are almost identical. The first stage is a differential amplifier made of two 6AU6 tubes. The second stage is a differential amplifier made of both halves of a 6BQ7A.

Pictures