The '''Tektronix 570''' is a curve tracer for tubes
{{Instrument Sidebar
It was introduced in 1955.
|class=Curve Tracer
It sweeps the plate voltage between zero and a selectable maximum voltage
|manufacturer=Tektronix
while "stepping" the control grid through a set of voltages.   
|model=570
|summary=Curve tracer for tubes
|image=Tektronix-570-Outside-Front.jpg
|caption=Tektronix 570 front
|introduced=1955
|discontinued=(?)
|designers=John Kobbe
|manuals=
* [[Media:070-167.pdf|Tektronix 570 Manual 070-167]] (PDF, OCR, good quality)
* [[Media:070-359.pdf|Tektronix 570 Manual 070-359 (1963)]] (PDF, good quality)
* [https://w140.com/mmm/tek-570.pdf Tektronix 570 Manual (mediocre quality, PDF)]
* [https://w140.com/tek_fcp/tek_570_fac_cal.pdf Tektronix 570 Factory Calibration Procedure 1959 (PDF)]
* [[Media:Tek 570 fcp feb 1964.pdf|Tektronix 570 Factory Calibration Procedure 1964 (PDF)]]
* [[Media:Tek 570 fcp.pdf]]
}}
The '''Tektronix 570''' was Tek's first curve tracer.  It is a curve tracer for tubes, introduced in 1955.
It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.   


A selectable screen voltage is available for testing tubes with screens.  The plate voltage is measured and applied
A selectable screen voltage is available for testing tubes with screens.   
to the X-axis of the display.  The plate current is measured and amplified and
The plate voltage is measured and applied to the X-axis of the display.   
is applied to the Y-axis of the display.   
Plate current is measured and amplified and is applied to the Y-axis of the display.   
 
{{MissingSpecs}}
 
==Internals==


The 570 contains five transformers:
The 570 contains five transformers:
Line 13: Line 33:
* T401: multitap autotransformer for selecting peak plate voltage, feeds T310
* T401: multitap autotransformer for selecting peak plate voltage, feeds T310
* T501: transformer for floating supplies and screen voltage supply
* T501: transformer for floating supplies and screen voltage supply
* T620: transformer for 60kHz HV power oscillator for CRT voltages
* T620: transformer for 60 kHz HV power oscillator for CRT voltages


The screen supply is regulated and uses a [[6CD6GA]] tube as the series
The screen supply is regulated and uses a [[6CD6GA]] tube as the series regulator.
regulator.


The vertical and horizontal amplifiers are almost identical.   
The vertical and horizontal amplifiers are almost identical.   
Line 22: Line 41:
The second stage is a differential amplifier made of both halves of a [[6BQ7A]].
The second stage is a differential amplifier made of both halves of a [[6BQ7A]].


* [http://w140.com/tek_570_rk.pdf Tektronix 570 Manual 070-167 (good quality, OCR, PDF)]
A [[T0520|T52P1]] CRT is standard in the 570.
* [http://w140.com/tek_570_manual_070-359_7-63.pdf Tektronix 570 Manual (good quality, PDF)]
 
* [http://w140.com/mmm/tek-570.pdf Tektronix 570 Manual (mediocre quality, PDF)]
==Pictures==
* [http://w140.com/tek_fcp/tek_570_fac_cal.pdf Tektronix 570 Factory Calibration Procedure (PDF)]


=== Early Tektronix 570 (Brown Era) ===
<gallery>
Tek570-test-setup.jpg
Tek 570 top controls and storage.jpg
</gallery>
===Tektronix 570 Serial Number 5010===
<gallery>
Tektronix-570-Outside-Front.jpg
Tektronix-570-Inside-Right.jpg
Tektronix-570-Inside-Left.jpg
Tektronix-570-Inside-Left-Close2.jpg
Tektronix-570-Inside-Bottom.jpg
Tektronix-570-Inside-Left-Close.jpg
Tektronix-570-Outside-Front-Close2.jpg
Tektronix-570-Inside-Right-Close3.jpg
</gallery>
=== Tektronix 570 Serial Number 5055 ===
<gallery>
tek_570_sn5055_1.jpg
tek_570_sn5055_2.jpg
tek_570_sn5055_3.jpg
tek_570_sn5055_4.jpg
tek_570_sn5055_5.jpg
tek_570_sn5055_6.jpg
tek_570_sn5055_7.jpg
tek_570_sn5055_8.jpg
tek_570_sn5055_9.jpg
tek_570_sn5055_10.jpg
tek_570_sn5055_11.jpg
tek_570_sn5055_12.jpg
</gallery>
=== Tektronix 570 Serial Number 5148 ===
<gallery>
tek_570_sn5148_1.jpg
tek_570_sn5148_2.jpg
tek_570_sn5148_3.jpg
tek_570_sn5148_4.jpg
tek_570_sn5148_5.jpg
tek_570_sn5148_6.jpg
tek_570_sn5148_7.jpg
tek_570_sn5148_8.jpg
tek_570_sn5148_9.jpg
tek_570_sn5148_10.jpg
tek_570_sn5148_11.jpg
tek_570_sn5148_12.jpg
</gallery>
=== Tektronix 570 Serial Number 5429 ===
<gallery>
<gallery>
Image:Tektronix-570-Outside-Front.jpg
Tek 570 sn5429 1.jpg
Image:Tektronix-570-Inside-Right.jpg
Tek 570 sn5429 2.jpg
Image:Tektronix-570-Inside-Left.jpg
Tek 570 sn5429 3.jpg
Image:Tektronix-570-Inside-Left-Close2.jpg
Tek 570 sn5429 4.jpg
Image:Tektronix-570-Inside-Bottom.jpg
Tek 570 sn5429 5.jpg
Image:Tektronix-570-Inside-Left-Close.jpg
Tek 570 sn5429 6.jpg
Image:Tektronix-570-Outside-Front-Close2.jpg
Tek 570 sn5429 7.jpg
Image:Tektronix-570-Inside-Right-Close3.jpg
Image:Tek 570 top controls and storage.jpg
</gallery>
</gallery>


 
===Adaptors for Different Tube Bases===
<gallery>
Tek 570 12-pin fixture 1.jpg|12-pin adaptor
Tek 570 12-pin fixture 2.jpg|12-pin adaptor
Tek 570 seven pin miniature adapter 1.jpg|7-pin miniature adaptor
Tek 570 seven pin miniature adapter 2.jpg|7-pin miniature adaptor
Tek 570 assorted adapters.jpg
</gallery>
[[Category:Curve tracers]]
[[Category:Curve tracers]]


[[Category:Specifications needed]]
[[Category:Specifications needed]]
[[Category:Introduced in 1955]]
[[Category:Introduced in 1955]]

Revision as of 13:08, 4 March 2022

Tektronix 570
Curve tracer for tubes
Tektronix 570 front

Produced from 1955 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 570 was Tek's first curve tracer. It is a curve tracer for tubes, introduced in 1955. It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.

A selectable screen voltage is available for testing tubes with screens. The plate voltage is measured and applied to the X-axis of the display. Plate current is measured and amplified and is applied to the Y-axis of the display.

Key Specifications

  • please add

Internals

The 570 contains five transformers:

  • T310: center-tapped isolation transformer for plate sweep
  • T340: multitap transformer for heater voltages
  • T401: multitap autotransformer for selecting peak plate voltage, feeds T310
  • T501: transformer for floating supplies and screen voltage supply
  • T620: transformer for 60 kHz HV power oscillator for CRT voltages

The screen supply is regulated and uses a 6CD6GA tube as the series regulator.

The vertical and horizontal amplifiers are almost identical. The first stage is a differential amplifier made of two 6AU6 tubes. The second stage is a differential amplifier made of both halves of a 6BQ7A.

A T52P1 CRT is standard in the 570.