581: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 7: Line 7:
summary=100 MHz (85 MHz) oscilloscope|
summary=100 MHz (85 MHz) oscilloscope|
manuals=
manuals=
* [http://w140.com/tek_581_sn1273.pdf Tektronix 581 Manual (PDF)]
* [[Media:070-170.pdf|Tektronix 581 Manual]] (PDF)
* [http://w140.com/581a_by_matt.pdf Tektronix 581A Manual (PDF)]
* [[Media:070-390.pdf|Tektronix 581A Manual (10M PDF, OCR)]]
<small>
* Factory Calibration Procedure: [[Media:Tek 581a fcp dec 1968.pdf|Dec 1968]] / [[Media:Tek 581a fcp march 1967.pdf|March 1967]]
* [[Media:Service Scope 39 Aug 1966.pdf|580 series gain adjustment procedure, in Service Scope 39, Aug 1966]]
* [[Media:Service Scope 39 Aug 1966.pdf|580 series gain adjustment procedure, in Service Scope 39, Aug 1966]]
* [[Media:Tek 581a fcp dec 1968.pdf]]
* [[Media:Tek 581a fcp march 1967.pdf]]
}}
}}



Revision as of 12:50, 27 May 2021

{{{manufacturer}}} 
100 MHz (85 MHz) oscilloscope
Tektronix 581 (early model)

Produced from 1959 to 1972

Manuals

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 581 is a 100 MHz tube scope introduced in 1959 as a single time base version of the 585. Like all 580-series scopes, it uses 580-series plug-ins.

The 58x series were the first Tektronix scopes to use distributed deflection plates and the last to use distributed amplifiers for vertical deflection. At 100 MHz (down-rated to 95 MHz in 1962 and 85 MHz for the 581A) with the Type 80 plug-in and up to 85 MHz with the dual-channel Type 82, they were the highest-speed general purpose scopes of Tek's tube scope era (the 1 GHz 519 was specialized with no vertical amplifier).

The vertical signal path of the 581 is the same as that of the 585. It uses the T581 CRT. Type 581 scopes with serial numbers up to 510 use an all-tube trigger circuit. Starting at serial number 511, the 581 uses tunnel diode triggering.

A Type 581A was introduced in 1963, and it is specified to have a bandwidth of 85 MHz instead of 100 MHz. The somewhat relaxed bandwidth specification improved CRT production yield which had been a problem when the scope was specified to 100 MHz.

Key Specifications

Rise time 3.5 ns with Type 80 plugin and P80 probe
Timebase 50 ns/Div to 2 s/Div, 1−2−5, variable ×2.5, magnifier ×5, single sweep; X input
CRT T581, distributed vertical deflection plates, 10 kV acceleration
Outputs A Sawtooth, A Gate, B Gate, Calibrator (0.2 mV to 100 Vp-p, 1−2−5)

Pictures

581

581A

Schematics