The Tektronix 661 is a sampling scope made by Tektronix in the 1960's. It accepts two plug-ins: a sampling unit and a timing unit. At least three sampling units were made, the 4S1 (1GHz) and the 4S2 (3.9GHz), and the 4S3. At least three timing units were made, the 5T1, 5T1A, and the 5T3. The timing units use tunnel diode triggering. Two coaxial cables in the scope connect the sampling unit to the timing unit. One cable sends the trigger pickoff signal from the sampling unit to the timing unit. The other cable sends the timing signal from the timing unit to the sampling unit, telling it when to sample.

The mainframe of the 661 is quite simple. It contains a calibration signal generator and a high-speed pulse generator, but otherwise is basically just a low-speed X-Y indicator. The total CRT accelerating voltage is just 3kV and the vertical and horizontal amplifiers are relatively mild differential amplifiers made of 6DJ8 tubes. The sophistication of the 661 is all in the plug-ins. The signal from the calibration generator is available on the front panel and is also sent to the timing generator through the multi-pin plug-in connector. This allows the timing plug-ins to select "CAL" as a trigger source. In this mode, the calibration generator can be used as the simulation for the device under test. In many situations, this eliminates the need for external triggering. When the timing unit triggers, a pulse is sent to the high-speed delayed pulse generator in the 661, which triggers and outputs a positive 250mV pulse about 400 nanoseconds long. The rising edge of this pulse is very fast.

The 4S1 is a dual-trace sampling unit for the 661. Each channel has a trigger pickoff, a delay line, and a sampler. The sampling pulses for each channel are generated by a step recovery diode are are fed to a sampling bridge made with of GaAs diodes. These diodes are fragile and exact replacements are hard to find. People have improvised replacements using modern integrated Schottky diodes such as those in HP/Agilent's HSMS-28x series. The 4S1 has a dual-trace mode, where the A waveform and the B waveform are both displayed in the time domain at the same time with a single trigger source and a single equivalent-time sweep rate. Another mode of is called "A vert/B horiz". This mode is used in conjunction with an X-Y mode switch on the panel of the 661 to allow arbitrary external control of the sampling point instead of a linear or random equivalent-time sweep.

Based on the available schematics, the 661 appears to have been designed in 1961. During what years was it manufactured? Why is it that the 661 has a dedicated high-speed coaxial interface between the sampling unit and the timing unit and later 560-series sampling systems (3S2, 3T77A, etc.) are able to simply use the regular plug-in connector and mainframe wiring harness for routing trigger and timing signals between the two units?