67: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
title=Tektronix Type 67 |
|manufacturer=Tektronix
summary=Timebase plug-in |
|series=560-series scopes
image=Tek67-crop.jpg |
|type=Type 67  
caption=Type 67 front view |
|summary=Timebase plug-in  
introduced=1961 |
|image=Tek67-crop.jpg  
discontinued=(?) |
|caption=Type 67 front view  
series=[[560-series scopes]]|
|introduced=1961  
manuals=
|discontinued=(?)  
|designers=
|manuals=
* [http://w140.com/mmm/tek-67.pdf Tektronix Type 67 Manual (PDF)]
* [http://w140.com/mmm/tek-67.pdf Tektronix Type 67 Manual (PDF)]
* [http://bama.edebris.com/download/tek/67/67.djvu Tektronix Type 67 Manual (DjVu)]
* [http://bama.edebris.com/download/tek/67/67.djvu Tektronix Type 67 Manual (DjVu)]

Revision as of 10:16, 13 August 2021

Tektronix Type 67
Timebase plug-in
Type 67 front view

Compatible with 560-series scopes

Produced from 1961 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 67 is a time-base for 560-series scopes, providing calibrated sweep rates from 1 μs/div to 5 s/div, introduced in 1961. The unmodified 67 does not have a single-sweep mode.

It uses a 6DJ8 as the trigger input amplifier, followed by another 6DJ8 as a Schmitt trigger. The 67 was replaced by the 2B67 which is very similar but has a single-sweep mode.

Mod 104

'Mod 104' is a factory modification to the Type 67 that gives the timebase single sweep capability. It is not documented in the service manual.

Although it is unknown how many Type 67s were fitted with 'Mod 104', there is at least one that exists with the modification.

Key Specifications

Sweep Rate 1 μs/div to 5 s/div
Vernier Range 1 μs/div to 12 s/div
Max. Magnification
Triggering Auto, Manual, Free Run
Ext. Input Sensitivity 1 V/div
     — With Mod 104
Sweep Mode Normal, Single

Pictures