7A14: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 16: Line 16:
In the 7A14, the ring around the input [[BNC connector]] that is used to identify ×10/×100 probes on voltage probes serves the purpose of detecting the difference between the P6021 and P6022 probes, and switching in appropriate gain and frequency compensation.  The P6021 shorts this ring to ground, directly switching three relays connected to -15 V internally.
In the 7A14, the ring around the input [[BNC connector]] that is used to identify ×10/×100 probes on voltage probes serves the purpose of detecting the difference between the P6021 and P6022 probes, and switching in appropriate gain and frequency compensation.  The P6021 shorts this ring to ground, directly switching three relays connected to -15 V internally.


The front panel gain control screwdriver adjustment affects gain for either P6021 or P6022. 
==Specifications==
==Specifications==


Line 30: Line 31:
The 7A14 uses twelve Tek-made [[miniature relays]] that can be a service issue.
The 7A14 uses twelve Tek-made [[miniature relays]] that can be a service issue.


The amplifier is an 8-stage discrete differential design.  The plugin contains no integrated circuits.
The amplifier is an 8-stage discrete differential design.  The plug-in contains no integrated circuits.


==Pictures==
==Pictures==

Revision as of 09:10, 9 January 2018

Template:Plugin Sidebar 2

The Tektronix 7A14 is a 120 MHz current probe amplifier vertical plug-in for 7000-series scopes. It is intended for current probes P6021 and P6022.

In the 7A14, the ring around the input BNC connector that is used to identify ×10/×100 probes on voltage probes serves the purpose of detecting the difference between the P6021 and P6022 probes, and switching in appropriate gain and frequency compensation. The P6021 shorts this ring to ground, directly switching three relays connected to -15 V internally.

The front panel gain control screwdriver adjustment affects gain for either P6021 or P6022.

Specifications

  • Bandwidth: 25 Hz – 50 MHz (P6021 Probe)
  • Bandwidth: 250 Hz – 105 MHz (P6022 Probe)
  • Ranges: 1 mA/Div to 1 A/Div in 1–2–5 sequence

Links

Internals

The 7A14 uses twelve Tek-made miniature relays that can be a service issue.

The amplifier is an 8-stage discrete differential design. The plug-in contains no integrated circuits.

Pictures