7B10: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar  
manufacturer=Tektronix | type=7B10|
|manufacturer=Tektronix  
summary=1 GHz Timebase|
|type=7B10
image=Tek-7b10-front.jpg |  
|summary=1 GHz Timebase
caption=Tektronix 7B10 front |
|image=Tek-7b10-front.jpg  
introduced=1978 |
|caption=Tektronix 7B10 front
discontinued=1990 |
|introduced=1978
series=7000-series scopes|
|discontinued=1990
manuals=
|series=7000-series scopes
|designers=Art Metz;Bruce Hofer
|manuals=
* [http://bama.edebris.com/download/tek/7b10/7b10.pdf Tektronix 7B10 Manual (PDF)]
* [http://bama.edebris.com/download/tek/7b10/7b10.pdf Tektronix 7B10 Manual (PDF)]
* [http://w140.com/smb/7b10_op_sm.pdf Tektronix 7B10 Operators Manual (OCR, PDF)]
* [http://w140.com/smb/7b10_op_sm.pdf Tektronix 7B10 Operators Manual (OCR, PDF)]

Revision as of 06:34, 9 August 2021

Tektronix 7B10
1 GHz Timebase
Tektronix 7B10 front

Compatible with 7000-series scopes

Produced from 1978 to 1990

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 7B10 is a 1 GHz time base for 7000-series scopes, in particular, the 1 GHz 7104 (typically used with 7A29 vertical amplifiers and a 7B15 delaying time base).

In effect, the 7B15/7B10 pair are improved-speed versions of the 7B85/7B80.

Key Specifications

Sweep 200 ms/Div to 2 ns/Div in 1−2−5 sequence, ×10 magnifier down to 200 ps/Div, variable to ×2.5
Excluded portions of sweep None in 7104/R7103, first 5 ns in 78xx, 79xx mainframes
Trigger sensitivity 0.5 Div (int) or 50 mV (ext) up to 250 MHz, 1.5 Div or 150 mV from 250 MHz to 1 GHz; HF SYNC mode: 0.3 Div or 75 mV, 250 MHz to 1 GHz
Trigger coupling DC, AC (>30 Hz), AC HF REJ (30 Hz to 30 kHz), AC LF REJ (>50 kHz)
Trigger input 50 Ω, max. 1 W average or 1 MΩ // 20 pF, max. 250 V DC+peak AC
Jitter less than 30 ps at 1 GHz
Features
  • Variable Trigger Holdoff
  • HF Sync mode

Internals

The trigger amplifier and switch function is performed by a 155-0160-00. The trigger is the 155-0150-00. Sweep control and lockout is performed by a 155-0149-00 or 155-0049-02.

Links

Pictures