7B50: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(8 intermediate revisions by 2 users not shown)
Line 6: Line 6:
|caption=7B50 front  
|caption=7B50 front  
|introduced=1969
|introduced=1969
|discontinued=1988
|discontinued=1975
|series=7000-series scopes
|series=7000-series scopes
|designers=Murlan Kaufman  
|designers=Murlan Kaufman
|manuals=
|manuals=
'''7B50'''
* [[Media:070-0975-00.pdf|Tektronix 7B50 Manual]] (OCR)
* [[Media:070-0975-00.pdf|Tektronix 7B50 Manual]] (OCR)
* [http://bama.edebris.com/download/tek/7b50/tek-7b50.pdf Tektronix 7B50 Manual @ BAMA] (PDF)
'''7B50A'''
* [[Media:070-1986-00.pdf|Tektronix 7B50A Manual]]
}}
}}
The '''Tektronix 7B50''' is a timebase plug-in for [[7000-series scopes]], particularly the 7500 series.
The '''Tektronix 7B50''' is a timebase plug-in for [[7000-series scopes]], particularly the 7500 series, [[introduced in 1969]].
It is specified for triggering up to 100 MHz. Triggering uses [[tunnel diodes]].  
It is specified for triggering up to 100 MHz. Triggering uses [[tunnel diodes]].  
The sweep is fully discrete, no ICs.
The sweep is fully discrete, no ICs. It was replaced by the [[7B50A]] in 1976.
There is a 7B50 and a 7B50A.


The task of designing the 7B50 was inherited and completed by [[Murlan Kaufman]].
The task of designing the 7B50 was inherited and completed by [[Murlan Kaufman]].


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec | Sweep | 5 s/Div to 50 ns/Div in 1−2−5 sequence, ×10 magnifier down to 5 ns/Div, variable down to 12.5 s/Div}}
{{Spec | Excluded portions of sweep | None in 7700-series, first 50 ns with magnifier }}
{{Spec | Trigger sensitivity | 0.3 Div (int) or 150 mV (ext) up to 10 MHz, 1.5 Div or 750 mV from 10 MHz to 100 MHz }}
{{Spec | Trigger coupling | DC, AC (>16 Hz), AC HF REJ (16 Hz to 100 kHz), AC LF REJ (>75 kHz) }}
{{Spec | Trigger input | 1 MΩ // 20 pF max. 500 V DC+peak AC }}
{{Spec | Jitter | less than 1 ns at 75 MHz }}
{{Spec | Trigger Modes | Peak-Peak Auto, Auto, Norm, Single Sweep}}
{{Spec | External horizontal amplifier | 90 mV/Div or 900 mV/Div ranges, 10:1 variable}}
{{EndSpecs}}


==X-Y operation==
==X-Y operation==
The 7B50 has a dedicated switch to put it in "amplifier mode" for X-Y operation.   
The 7B50 has a dedicated switch to put it in "amplifier mode" for X-Y operation.   
In this mode, the Trigger Source switch controls the signal source – internal from a vertical plug-in via the trigger path, or external — and the Trigger Coupling switch controls AC vs. DC coupling.  
In this mode, the Trigger Source switch controls the signal source – internal from a vertical plug-in via the trigger path, or external — and the Trigger Coupling switch controls AC vs. DC coupling.  
In amplifier mode, gain can be varied using an uncalibrated potentiometer.
In amplifier mode, gain can be varied using an uncalibrated potentiometer.
==Links==
{{Documents|Link=7B50}}


==Pictures==
==Pictures==
<gallery>
<gallery>
Tek 7b50.jpg|7B50
Tek 7b50.jpg|7B50
Tek 7b50a.jpg|7B50A
Tek 7b50a front2.jpg|7B50A
Tek 7b50a bottom2.jpg|7B50A bottom
Tek 7b50a rear2.jpg|7B50A rear
Tek 7b50a top2.jpg|7B50A top
Tek 7a17 7a18 7b50a model3 cart.jpg
Tek 7b50 front close.jpg|7B50
Tek 7b50 front close.jpg|7B50
Tek 7b50 34 close.jpg|7B50
Tek 7b50 34 close.jpg|7B50
</gallery>
</gallery>
{{Custom ICs|7B50}}
{{Custom ICs|7B50A}}






[[Category:7000 series horizontal plugins]]
[[Category:7000 series horizontal plugins]]

Latest revision as of 07:29, 16 November 2023

Tektronix 7B50
100 MHz Timebase
7B50 front

Compatible with 7000-series scopes

Produced from 1969 to 1975

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 7B50 is a timebase plug-in for 7000-series scopes, particularly the 7500 series, introduced in 1969. It is specified for triggering up to 100 MHz. Triggering uses tunnel diodes. The sweep is fully discrete, no ICs. It was replaced by the 7B50A in 1976.

The task of designing the 7B50 was inherited and completed by Murlan Kaufman.

Key Specifications

Sweep 5 s/Div to 50 ns/Div in 1−2−5 sequence, ×10 magnifier down to 5 ns/Div, variable down to 12.5 s/Div
Excluded portions of sweep None in 7700-series, first 50 ns with magnifier
Trigger sensitivity 0.3 Div (int) or 150 mV (ext) up to 10 MHz, 1.5 Div or 750 mV from 10 MHz to 100 MHz
Trigger coupling DC, AC (>16 Hz), AC HF REJ (16 Hz to 100 kHz), AC LF REJ (>75 kHz)
Trigger input 1 MΩ // 20 pF max. 500 V DC+peak AC
Jitter less than 1 ns at 75 MHz
Trigger Modes Peak-Peak Auto, Auto, Norm, Single Sweep
External horizontal amplifier 90 mV/Div or 900 mV/Div ranges, 10:1 variable

X-Y operation

The 7B50 has a dedicated switch to put it in "amplifier mode" for X-Y operation. In this mode, the Trigger Source switch controls the signal source – internal from a vertical plug-in via the trigger path, or external — and the Trigger Coupling switch controls AC vs. DC coupling. In amplifier mode, gain can be varied using an uncalibrated potentiometer.

Links

Documents Referencing 7B50

Document Class Title Authors Year Links
Tekscope 1969 V1 N5 Oct 1969.pdf Article Introducing the New Generation 1969
Tekscope 1969 V1 N6 Dec 1969.pdf Article A New Logic for Oscilloscope Displays 1969

Pictures