84: Difference between revisions

No edit summary
No edit summary
 
(12 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
title=Tektronix Type 84|
|manufacturer=Tektronix
summary=Calibration Fixture|
|series=580-series scopes
image=067-0523-00 cat.jpg |  
|type=84
caption=Type 84|
|summary=calibration fixture
introduced=1962 |
|image=Tek 067-0523-00 front.jpg
discontinued=(?) |
|caption=Type 84
series=[[580-series scopes]]|
|introduced=1962  
manuals=
|discontinued=(?)  
* [http://w140.com/tek_84.pdf Tektronix Type 84 Manual (PDF)]
|designers=John Gates;
* [[Media:067-0523-00 schematic.pdf|Tektronix 067-0523-00 Schematic (PDF)]]
|manuals=
* [[Media:070-0345-01.pdf|Tektronix 067-0523-00 Manual (PDF, OCR)]]
* [[Media:070-0345-01.pdf|Tektronix 067-0523-00 Manual]] (OCR)
* [[Media:067-0523-00 schematic.pdf|Tektronix 067-0523-00 Schematic]]
* [[Media:Tek 067-0523-00 fcp aug 1966.pdf|Tektronix 067-0523-00 Factory Calibration Procedure, August 1966]]
}}
}}
The '''Tektronix Type 84''' is a calibration fixture plug-in for [[580-series scopes]].


The '''Tektronix Type 84''' is a calibration fixture plug-in for [[580-series scopes]].
It was renamed the '''067-0523-00''' during production (SN 974+).


It was renamed the '''067-0523-00''' during production.  The Type 84 provides a
The Type 84 provides a calibrated amplitude signal for adjusting gain,  
calibrated amplitude signal for adjusting gain, a fast-rise voltage step
a fast-rise voltage step – produced by a [[mercury switch]] – for adjusting the impulse response of the vertical amplifiers in the scope,
for adjusting the impulse response of the vertical amplifiers in the scope,
and load resistors to test the power supply of the scope.   
and load resistors to test the power supply of the scope.  The fast-rise
It also features an external input to connect a time-mark generator during calibration.
pulses are produced by a [[mercury switch]] and are specified to have a  
repetition rate of 550 to 750 pulses per second, with a rise time that is
''"considerably less than the response time of the vertical amplifier in a 580-series oscilloscope." ''


==Specifications==
{{BeginSpecs}}
[[Category:Specifications needed]] ''please add''
{{Spec | Display signal | Calibration signal, fast-rise pulses, or external }}
{{Spec | Calibration reference signal | 200 mV, front-panel check }}
{{Spec | Pulse amplitude | Adjustable to plus or minus 4 cm deflection }}
{{Spec | Pulse repetition rate | 550 to 750 pulses per second }}
{{Spec | Pulse rise time | "considerably less than the response time of the vertical amplifier in a 580-series oscilloscope." }}
{{EndSpecs}}


==Pictures==
==Pictures==
<gallery>
<gallery>
File:067-0523-00 cat.jpg
Tek 067-0523-00 front.jpg | 067-0523-00 Front
Image:Type-84-schem.png
Tel_84_Front.jpeg          | Type 84 Front
Image:Tek 067-0523-00.jpg
Tek 067-0523-00.jpg
Tek 067-0523-00 1.jpg|067-0523-00
Tek 067-0523-00 1.jpg | 067-0523-00
Tek 067-0523-00 2.jpg|067-0523-00
Tek 067-0523-00 2.jpg | 067-0523-00
Tek 067-0523-00 3.jpg|067-0523-00
Tek 067-0523-00 3.jpg | 067-0523-00
Tek 067-0523-00 4.jpg|067-0523-00
Tek 067-0523-00 4.jpg | 067-0523-00
Tek 84 1.jpg|84
Tek 84 1.jpg
Tek 84 2.jpg|84
Tek 84 2.jpg
Tek 84 3.jpg|84
Tek 84 3.jpg
Tek 84 4.jpg|84
Tek 84 4.jpg
Tek 067-0523-00 internal1.jpg | 067-0523-00
Tek 067-0523-00 internal2.jpg | 067-0523-00
Tek 067-0523-00 rear.jpg      | 067-0523-00
Tek 067-0523-00 10.jpeg | 067-0523-00
Tek 067-0523-00 12.jpeg | 067-0523-00
Tek 067-0523-00 13.jpeg | 067-0523-00
Tek 067-0523-00 14.jpeg | 067-0523-00
Tek 067-0523-00 5.jpeg | 067-0523-00
Tek 067-0523-00 6.jpeg | 067-0523-00
Tek 067-0523-00 7.jpeg | 067-0523-00
</gallery>


'''Schematics'''
<gallery>
Type-84-schem.png
</gallery>
</gallery>



Latest revision as of 08:43, 8 December 2023

The Tektronix Type 84 is a calibration fixture plug-in for 580-series scopes.

Tektronix 84
calibration fixture
Type 84

Compatible with 580-series scopes

Produced from 1962 to (?)

Manuals

It was renamed the 067-0523-00 during production (SN 974+).

The Type 84 provides a calibrated amplitude signal for adjusting gain, a fast-rise voltage step – produced by a mercury switch – for adjusting the impulse response of the vertical amplifiers in the scope, and load resistors to test the power supply of the scope. It also features an external input to connect a time-mark generator during calibration.

Key Specifications

Display signal Calibration signal, fast-rise pulses, or external
Calibration reference signal 200 mV, front-panel check
Pulse amplitude Adjustable to plus or minus 4 cm deflection
Pulse repetition rate 550 to 750 pulses per second
Pulse rise time "considerably less than the response time of the vertical amplifier in a 580-series oscilloscope."

Pictures

Schematics