CT-5: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "* [http://w140.com/tek_ct5.pdf Tektronix CT-5 Manual (PDF)]")
 
No edit summary
 
(7 intermediate revisions by 3 users not shown)
Line 1: Line 1:
* [http://w140.com/tek_ct5.pdf Tektronix CT-5 Manual (PDF)]
{{Probe Sidebar
|manufacturer=Tektronix
|model=CT-5
|summary=High Current Transformer
|image=Tek ct-5 1.JPG
|caption=CT-5 High Current Transformer
|for=A6302
|introduced=1971
|discontinued=(?)
|manuals=
* [[Media:070-1130-00.pdf|Tektronix CT-5 Manual]]
}}
The '''Tektronix CT-5 High Current Transformer''' is designed to extend the range of an [[A6302]] probe (with [[AM503]] amplifier) or [[P6021]] probe by a factor of 1000 (up to 5000 A/Div).
 
{{BeginSpecs}}
{{Spec | Bandwidth              | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil}}
{{Spec | Risetime              | 17.5 ns }}
{{Spec | Maximum pulsed current | 50 kA peak (with dearating)}}
{{Spec | Accuracy              | 4 % }}
{{Spec | Attenuation            | 20:1 or 1000:1 }}
{{Spec | Input impedance        | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz }}
{{Spec | Max. input voltage    | 3000 V (bare conductor) }}
{{EndSpecs}}
 
==Pictures==
<gallery>
Tek CT-5 Box close.jpeg
Tek CT-5 Box open.jpeg
Tek CT-5 Box label.jpeg
Tek CT-5 Probe left.jpeg
Tek CT-5 Probe right.jpeg
Tek CT-5 Probe open.jpeg
Tek CT-5 Probe connection.jpeg
Tek CT-5 DC bucking coil right.jpeg
Tek CT-5 DC bucking coil left.jpeg
Tek ct-5 1.JPG
Tek ct-5 2.JPG
</gallery>
 
[[Category:Oscilloscope current probes]]

Latest revision as of 06:43, 22 November 2023

Tektronix CT-5
High Current Transformer
CT-5 High Current Transformer

Compatible with A6302

Produced from 1971 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix CT-5 High Current Transformer is designed to extend the range of an A6302 probe (with AM503 amplifier) or P6021 probe by a factor of 1000 (up to 5000 A/Div).

Key Specifications

Bandwidth 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil
Risetime 17.5 ns
Maximum pulsed current 50 kA peak (with dearating)
Accuracy 4 %
Attenuation 20:1 or 1000:1
Input impedance 20 µΩ at 60 Hz to 30 mΩ at 1 MHz
Max. input voltage 3000 V (bare conductor)

Pictures