DC503/Repairs: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "==Repair Issues== * If no LED or display segment is lit after trun on, check for +15 V from U500 Voltage regulator IC type 723. * All ICs are placed in IC sockets. Contact pr...")
(No difference)

Revision as of 09:57, 26 January 2023

Repair Issues

  • If no LED or display segment is lit after trun on, check for +15 V from U500 Voltage regulator IC type 723.
  • All ICs are placed in IC sockets. Contact problems can occur. Removing and inserting ICs helps.
  • Check board is mounted to frame with plastic washers in between near pcb conductor tracks, otherwise a short to GND can occur.