L: Difference between revisions

Jump to navigation Jump to search
1,288 bytes added ,  16 November 2019
m
Circuit Summary
No edit summary
m (Circuit Summary)
(4 intermediate revisions by 3 users not shown)
Line 11: Line 11:
* [http://w140.com/tek_fcp/tek_type_l_factory_cal_proc.pdf Tektronix Type L Factory Calibration Procedure (PDF)]
* [http://w140.com/tek_fcp/tek_type_l_factory_cal_proc.pdf Tektronix Type L Factory Calibration Procedure (PDF)]


* [[Media:tek_type_l_fcp.pdf|Tektronix Type L Factory Calibration Procedure (PDF, OCR)]]
* [[Media:070-336.pdf|Tektronix Type L Manual (PDF, OCR, bad-OCR)]]
* [[Media:tek_type_l_fcp.pdf|Tektronix Type L Factory Calibration Procedure (PDF, OCR, bad-OCR)]]
}}
}}
The '''Tektronix Type L''' is an amplifier plug-in for [[500-series scopes]].
The '''Tektronix Type L''' is an amplifier plug-in for [[500-series scopes]].
Line 32: Line 33:


{{MissingSpecs}}
{{MissingSpecs}}
==Internals==
The input is switched via a Frequency compensated attenuator network which is controlled by the Vols/CM Switch.
Input is then coupled to first cathode follower V5832, a 5654/6AK5W RF Pentode. This is configured as a cathode follower.
The screen supply of this  cathode follower is switched from +100 to a decoupled network from +225V rail when the X10 Mode is selected.
The output of input amplifier is then switched via a 10X Amplifier - if the X10 mode is selected in the front panel - or directly to the paraphase or phase inverter made up of two [[12AU6]] tubes. This stage converts the input signal to a differential push-pull output. This output is passed to the final output drivers, which are two cathode follower sections with a pair of [[12AT7]] tubes. The differential output is then passed to pin 1 and 3 of the connector to drive the vertical amplifier inside the chassis.
The 10X amplifier stage is built with 3 5654/6AK5W tubes. First two are configured as amplifier and the last one as  output cathode follower.
Heater for the tubes are derived from +75VDC heater supply available at pin 15 of the connector. This is to avoid any  interference/hum from the regular AC heater supply at 60Hz.


==Pictures==
==Pictures==
Line 41: Line 54:
Tek type l left.jpg
Tek type l left.jpg
Tek type l bottom.jpg
Tek type l bottom.jpg
Tek type l top2.jpg
Tek type l in 541a.jpg|Type L in [[541|541A]]
Tek type l in 541a.jpg|Type L in [[541|541A]]
Tek type l perf.png | Performance in Different Scopes
Tek type l perf.png | Performance in Different Scopes
1,537