The Tektronix P170CF is a cathode-follower probe intended for use with the [[517]].  The P170CF uses a [[5718]] tube.
[[File:Tek p170cf.jpg|thumb|350px|right]]
The '''Tektronix P170CF''' is a cathode-follower probe intended for use with the [[517|517 scope]], or a [[128|Type 128 power supply]].
It came with three attenuator heads.


The P170CF uses a [[5718]] triode.  It requires a 170 Ω termination which is built into the 517 and needs to be externally connected for other instruments (the ''B170-R'' terminator with [[UHF connector]]s was available for this).
{{BeginSpecs}}
{{Spec | Attenuation |
* Without attenuator: ×2
* With PAX-1 head: ×4 to ×40
* With PAX-2 head: ×20 to ×200
* With PAX-3 head: ×200 to ×2000 }}
{{Spec | Input impedance | With attenuators: 12 MΩ // 5 pF @ min att. − 1.2 pF @ max. att. }}
{{EndSpecs}}
==Links==
* The P170CF is discussed in the [[Media:070-063.pdf|Tektronix Type 128 manual (PDF)]]
==Pictures==
<gallery>
<gallery>
File:Tek p170cf.jpg
Tek p170cf.jpg
File:Tek p170 1961 cat.png
Tek p170 1961 cat.png
</gallery>
</gallery>


 
[[Category:Manual needed]]
[[Category:Active Ohm Oscilloscope Probes]]
[[Category:Active oscilloscope probes]]

Revision as of 13:14, 27 May 2021

The Tektronix P170CF is a cathode-follower probe intended for use with the 517 scope, or a Type 128 power supply. It came with three attenuator heads.

The P170CF uses a 5718 triode. It requires a 170 Ω termination which is built into the 517 and needs to be externally connected for other instruments (the B170-R terminator with UHF connectors was available for this).

Key Specifications

Attenuation
  • Without attenuator: ×2
  • With PAX-1 head: ×4 to ×40
  • With PAX-2 head: ×20 to ×200
  • With PAX-3 head: ×200 to ×2000
Input impedance With attenuators: 12 MΩ // 5 pF @ min att. − 1.2 pF @ max. att.