Line 19: Line 19:
{{Spec | Bandwidth | 25 MHz }}
{{Spec | Bandwidth | 25 MHz }}
{{Spec | Attenuation | 100× ±3% }}
{{Spec | Attenuation | 100× ±3% }}
{{Spec | Maximum Voltage | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies }}
{{Spec | Maximum input | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies }}
{{Spec | Input Impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }}
{{Spec | Input impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }}
{{Spec | Compensation Range | 15-55 pF }}
{{Spec | Compensation range | 15-55 pF }}
{{EndSpecs}}
{{EndSpecs}}



Revision as of 10:03, 21 January 2022

Tektronix P6007
25 MHz, 100×, HV, Passive Probe
P6007

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6007 is a medium voltage, 100×, passive probe for use with 1 MΩ input scopes. It has a BNC connector with no readout encoding pin.

Key Specifications

Bandwidth 25 MHz
Attenuation 100× ±3%
Maximum input 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies
Input impedance 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance
Compensation range 15-55 pF