P6022: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(misunderstanding of text - input is different, manual makes no mention)
Line 4: Line 4:
The sister model [[P6021]] has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.
The sister model [[P6021]] has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.


The P6022 can be used with the [[AM503#Background|AM503]].
==Specifications==
==Specifications==
{| class="wikitable"
{| class="wikitable"

Revision as of 15:02, 6 October 2016

The Tektronix P6022 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is at least 200 MHz with the passive termination.

Schematic (click to enlarge)

The sister model P6021 has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.

Specifications

P6021 passive P6021 + 134 P6022 passive P6022 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz
Maximum current 15 Ap-p 6 Ap-p
(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)

Manuals