[[File:p6042-complete.jpg|thumb|350px|right|P6042]]
{{Probe Sidebar
The '''Tektronix P6042''' is a DC to 50 MHz current probe [[introduced in 1967]].
|manufacturer=Tektronix
|model=P6042
|summary=DC−50 MHz current probe
|image=P6042-complete.jpg
|caption=P6042 complete
|for=50 Ω scope inputs
|introduced=1967
|discontinued=(?)
|designers=Cal Hongel
|manuals=
* [http://w140.com/tek_p6042.pdf Tektronix P6042 Manual (PDF)]
}}
The '''Tektronix P6042''' is a DC to 50 MHz current probe [[introduced in 1967]].  It was designed by [[Cal Hongel]].


The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components.   
The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components.   
Line 8: Line 20:


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | DC to 50 MHz (-3 dB) }}
{{Spec | Bandwidth | DC to 50 MHz (−3 dB) }}
{{Spec | Rise time | 7 ns }}
{{Spec | Rise time | 7 ns }}
{{Spec | Ranges | 1 mA/Div to 1 A/Div (1-2-5) }}
{{Spec | Ranges   | 1 mA/Div to 1 A/Div (1-2-5) }}
{{Spec | Output | to 50 Ω scope input at 50 mV/Div }}
{{Spec | Output   | to 50 Ω scope input at 50 mV/Div }}
{{Spec | Maximum input | 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges }}
{{Spec | Maximum input | 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges }}
{{Spec | Power | 90-136 or 180-272 V, 20 W}}
{{Spec | Power     | 90-136 or 180-272 V, 20 W}}
{{EndSpecs}}
{{EndSpecs}}
==Manuals==
* [http://w140.com/tek_p6042.pdf Tektronix P6042 Manual (PDF)]


==Links==
==Links==
Line 25: Line 34:
* [http://www.pa4tim.nl/?p=3135 P6042 repair by Fred, PA4TIM]
* [http://www.pa4tim.nl/?p=3135 P6042 repair by Fred, PA4TIM]
* [[Media:Service Scope 46 Oct 1967.pdf | Service Scope 46, October 1967]]
* [[Media:Service Scope 46 Oct 1967.pdf | Service Scope 46, October 1967]]
* [https://www.eetimes.com/author.asp?section_id=36&doc_id=1330593 P6042 teardown @ EEtimes]


==Pictures==
==Pictures==
<gallery>
<gallery>
File:p6042-front.jpg | amplifier front
p6042-front.jpg | amplifier front
File:p6042-complete.jpg | amplifier and sensor
p6042-complete.jpg | amplifier and sensor
File:p6042-sensor.jpg | sensor detail
p6042-sensor.jpg | sensor detail
File:p6042-back.jpg | rear view
p6042-back.jpg | rear view
File:P6042.png | catalog image
P6042.png | catalog image
Tek p6042 amp internal1.jpg|P6042 amplifier internal view
Tek p6042 amp internal2.jpg|P6042 amplifier internal view
Tek p6042 amp internal3.jpg|P6042 amplifier internal view
</gallery>
</gallery>




[[Category:Oscilloscope current probes]]
[[Category:Oscilloscope current probes]]
[[Category:Introduced in 1967]]

Revision as of 10:40, 31 August 2021

Tektronix P6042
DC−50 MHz current probe
P6042 complete

Compatible with 50 Ω scope inputs

Produced from 1967 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6042 is a DC to 50 MHz current probe introduced in 1967. It was designed by Cal Hongel.

The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components. The amplifier combines DC/LF and HF signals.

The AM503 is a redesign of the P6042.

Key Specifications

Bandwidth DC to 50 MHz (−3 dB)
Rise time 7 ns
Ranges 1 mA/Div to 1 A/Div (1-2-5)
Output to 50 Ω scope input at 50 mV/Div
Maximum input 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges
Power 90-136 or 180-272 V, 20 W