P6045: Difference between revisions

569 bytes added ,  22 December 2022
no edit summary
No edit summary
No edit summary
 
(13 intermediate revisions by 2 users not shown)
Line 1: Line 1:
The Tektronix P6045 is a 230MHz FET probe.  The signal amplitude range is 500mV.
{{Probe Sidebar
The offset can be set to any voltage from -1V to to 1V.  Attenuator heads can be
|manufacturer=Tektronix
placed on the tip of the P6045, reducing the capacitance, increasing the signal
|model=P6045
amplitude range, and of course reducing the sensitivity.
|summary=230 MHz FET probe
|image=p6045 box.jpg
|caption=Tektronix P6045
|for=454
|introduced=1967
|discontinued=(?)
|manuals=
* [[Media:070-0597-00.pdf|Tektronix P6045 Manual]]
}}
The '''Tektronix P6045''' is a 230 MHz FET probe.  It requires a ±12.5 V supply from a [[015-0073-00]] or a [[454]]/[[454A]] scope.


* [http://w140.com/TekP6045.pdf Tektronix P6045 Manual (PDF)]
Attenuator heads can be placed on the tip of the P6045, reducing the capacitance, increasing the signal amplitude range, and of course reducing the sensitivity.


It is possible that [[Glenn Bateman]] designed the P6045.
{{MissingSpecs}}
The signal amplitude range is 500 mV.
The offset can be set to any voltage from −1 V to to 1 V. 
==Links==
* [http://www.barrytech.com/tektronix/probes/tekp6045.html P6045] @ barrytech.com
==Pictures==
<gallery>
<gallery>
Image:Tek p6045 schem.png
Tek p6045 small.png |  schematic diagram
Tek 015-0073-00 output connector.png  | power connector
</gallery>
</gallery>