P6055: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(8 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix P6055''' is a 10× probe for differential amplifiers. | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6055 | |||
|summary=10× probe for differential applications | |||
|image=P6055 1.jpg | |||
|caption=Tektronix P6055 | |||
|for=1 MΩ scope inputs | |||
|introduced=1971 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-1115-00.pdf|Tektronix P6055 Manual]] (PDF) | |||
* [https://w140.com/tek_p6055_1971_cat.pdf Tektronix P6055 Description in 1971 Catalog (PDF)] | |||
}} | |||
[[File:P6055 2.jpg | thumb | 250px | right]] | |||
The '''Tektronix P6055''' is a 10× probe pair for differential amplifiers such as e.g. the [[7A13]] having 1 MΩ Inputs and 20 to 47 pF input capacity. | |||
The probe's resistive attenuation ratio is adjustable to an exact ×10 for the given amplifier input. | |||
This allows precise gain matching to improve CMRR. | |||
Tektronix also recommended the P6055 for the [[7D12]]/[[M2]] sample/hold, because of the trimming feature improving the accuracy of voltage readings. | |||
The P6055 has a [[readout pin]]. | |||
[[Category: | {{BeginSpecs}} | ||
[[Category: | {{Spec | Compensation Range | 1 MΩ//12-47 pF}} | ||
{{Spec | Attenuation | Adjustable to ×10 }} | |||
{{Spec|Input Impedance | 1 MΩ / 10-12.5 pF}} | |||
{{Spec| Step Response | < 4ns}} | |||
{{Spec | CMRR with [[7A13]] or [[1A5]]| 20,000:1 from DC - 1kHz, 100:1 at 20 MHz }} | |||
{{Spec | Max. input | ±500 V Maximum Common Mode Voltage }} | |||
{{EndSpecs}} | |||
[[Category:1 MΩ Oscilloscope probes]] | |||
[[Category:Passive Differential probes]] |
Revision as of 09:10, 19 August 2021
The Tektronix P6055 is a 10× probe pair for differential amplifiers such as e.g. the 7A13 having 1 MΩ Inputs and 20 to 47 pF input capacity. The probe's resistive attenuation ratio is adjustable to an exact ×10 for the given amplifier input. This allows precise gain matching to improve CMRR.
Tektronix also recommended the P6055 for the 7D12/M2 sample/hold, because of the trimming feature improving the accuracy of voltage readings.
The P6055 has a readout pin.
Key Specifications
Compensation Range | 1 MΩ//12-47 pF |
---|---|
Attenuation | Adjustable to ×10 |
Input Impedance | 1 MΩ / 10-12.5 pF |
Step Response | < 4ns |
CMRR with 7A13 or 1A5 | 20,000:1 from DC - 1kHz, 100:1 at 20 MHz |
Max. input | ±500 V Maximum Common Mode Voltage |