The Tektronix P6057 probe is a 100x version of the 10x [[P6056]].
[[File:P6056.jpg|thumb|350px|right|P6056 probe (otherwise identical ×10 sister model)]]
The '''Tektronix P6057''' is a 1.4 GHz ×100 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972.
 
It has an Identify switch and readout contact.
 
Its sister model [[P6056]] has ×10 attenuation.
 
{{BeginSpecs}}
{{Spec | Bandwidth | DC to 1.4 GHz }}
{{Spec | Rise time | 250 ps }}
{{Spec | Attenuation | 100× }}
{{Spec | Input impedance  | 5 kΩ // approx. 1 pF }}
{{Spec | Scope input impedance| 50 Ω }}
{{Spec | Maximum input Voltage| 50 V dc or RMS }}
{{Spec | Features | Readout Pin, ID Button }}
{{EndSpecs}}
 
==Manual==
 
* [http://w140.com/tek_P6056_P6057.pdf Tektronix P6056 and P6057 Manual (PDF)]
 
<blockquote>
<u>WARNING</u>:
This high performance device has a fragile resistor assembly in the<br />
probe head, subject to failure in rough usage.  Use with slip-on tip<br />
whenever possible.  One replacement part is provided with the package.<br />
Contact nearest Field Office for additional parts (P/N 307-0330-00), if<br />
required.  For replacement and Calibration Procedure, refer to Pg. 3 & 4<br />
of manual.
</blockquote>
 
 
 
 
[[Category:50 Ω Oscilloscope probes]]
[[Category:Introduced in 1972]]

Revision as of 21:29, 2 March 2021

P6056 probe (otherwise identical ×10 sister model)

The Tektronix P6057 is a 1.4 GHz ×100 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.

It has an Identify switch and readout contact.

Its sister model P6056 has ×10 attenuation.

Key Specifications

Bandwidth DC to 1.4 GHz
Rise time 250 ps
Attenuation 100×
Input impedance 5 kΩ // approx. 1 pF
Scope input impedance 50 Ω
Maximum input Voltage 50 V dc or RMS
Features Readout Pin, ID Button

Manual

WARNING:

This high performance device has a fragile resistor assembly in the
probe head, subject to failure in rough usage. Use with slip-on tip
whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4
of manual.