P6061: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 9: Line 9:
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* ''please add'' [[Category:Manual needed]]
* [[Media:070-1182-00.pdf|Tektronix P6061 Manual]]
}}
}}
The '''Tektronix P6061''' is a 10× probe for the [[453]] or [[7A18]], without an identify/readout feature.
The '''Tektronix P6061''' is a 10× probe with a plain BNC connector. A metal spring is provided to short the ring contact in [[432]], [[434]], and [[5000-series scopes|5100-series scopes]] to ground and provide proper 10x indication on the front panel of those instruments.  


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec | Attenuation        | ×10 }}
{{Spec | Bandwidth          | 60 MHz }}
{{Spec | Input impedance    | 10 MΩ // <9.5–13.5 pF, depending on cable length }}
{{Spec | Compensation range | 15-24 pF}}
{{Spec | Maximum voltage    | 500 V DC + peak AC }}
{{Spec | Cable length      | 3.5, 6, or 9 feet long, terminated in a [[BNC]] connector }}
{{EndSpecs}}


==Pictures==
==Pictures==

Latest revision as of 11:22, 14 February 2023

Tektronix P6061
10× probe for the 453 or 7A18
Tektronix P6061

Compatible with 1 MΩ scope inputs

Produced from 1971 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6061 is a 10× probe with a plain BNC connector. A metal spring is provided to short the ring contact in 432, 434, and 5100-series scopes to ground and provide proper 10x indication on the front panel of those instruments.

Key Specifications

Attenuation  ×10
Bandwidth 60 MHz
Input impedance 10 MΩ // <9.5–13.5 pF, depending on cable length
Compensation range 15-24 pF
Maximum voltage 500 V DC + peak AC
Cable length 3.5, 6, or 9 feet long, terminated in a BNC connector

Pictures