P6139: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(adding accessory set 020-1956-01)
No edit summary
Line 1: Line 1:
[[File:P6139A-full.jpg|thumb|350px|right|P6139A, full view]]
{{Probe Sidebar
|manufacturer=Tektronix
|model=P6139
|summary=500 MHz ×10 Passive Probe
|image=P6139A-full.jpg
|caption=Tektronix P6139A, full view
|for=1 MΩ scope inputs
|series=
|introduced=(?)
|discontinued=(?)
|manuals=
* [[Media:063-0870-05.pdf|Tektronix P6139A Manual]]
* [https://www.tek.com/sites/tek.com/files/media/media/resources/60W_15107_2_1.pdf P6131, P6137, P6138A data sheet]
'''Accessories'''
* [https://w140.com/tekwiki/wiki/020-1956-01 020-1956-01 Compact Probe Accessory Set]
}}
The '''Tektronix P6139''' is a passive 500 MHz ×10 scope probe for 1 MΩ // 8-18 pF scope inputs.
The '''Tektronix P6139''' is a passive 500 MHz ×10 scope probe for 1 MΩ // 8-18 pF scope inputs.


Line 17: Line 32:
Unless they've had their cables replaced, they had a whisker- or dendrite-growth problem in the cable that will short out the signal and drive you nuts.  It can be cleared by running some current through the BNC connector but only temporarily.  The only fix is to order a new cable from Tektronix, which I'm not sure you can still do.
Unless they've had their cables replaced, they had a whisker- or dendrite-growth problem in the cable that will short out the signal and drive you nuts.  It can be cleared by running some current through the BNC connector but only temporarily.  The only fix is to order a new cable from Tektronix, which I'm not sure you can still do.
</blockquote>
</blockquote>
==Accessories==
* [https://w140.com/tekwiki/wiki/020-1956-01 020-1956-01 Compact Probe Accessory Set]
==Manuals==
* [http://w140.com/tek_p6139a.pdf Tektronix P6139A Manual (PDF)]


==Links==
==Links==
* [http://www.tek.com/sites/tek.com/files/media/media/resources/60W_15107_2_1.pdf P6131, P6137, P6138A data sheet]]
* [http://www.barrytech.com/tektronix/probes/tekp6137.html P6137 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6137.html P6137 @ barrytech.com]


==Pictures==
==Pictures==
<gallery>
<gallery>
File:P6139A-full.jpg|P6139A, full view
P6139A-full.jpg|P6139A, full view
File:P6139A-head.jpg|P6139A, close-up of compensation box
P6139A-head.jpg|P6139A, close-up of compensation box
</gallery>
</gallery>



Revision as of 15:24, 20 July 2022

Tektronix P6139
500 MHz ×10 Passive Probe
Tektronix P6139A, full view

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6139 is a passive 500 MHz ×10 scope probe for 1 MΩ // 8-18 pF scope inputs.

It has a ×10 readout pin, and shares accessories with many other Tektronix compact modular probes.

Key Specifications

Attenuation 10×
Bandwidth 500 MHz
Input impedance 10 MΩ // 8 pF
Length 1.3 m
Intended for TDS500 series, TDS3052, TDS3054

Issues

According to KE5FX:

Unless they've had their cables replaced, they had a whisker- or dendrite-growth problem in the cable that will short out the signal and drive you nuts. It can be cleared by running some current through the BNC connector but only temporarily. The only fix is to order a new cable from Tektronix, which I'm not sure you can still do.

Links

Pictures