P6201: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (Pics)
(4 intermediate revisions by 4 users not shown)
Line 1: Line 1:
[[File:P6201_kit_new.JPG | thumb | 350px | right | Tektronix P6201]]
{{Oscilloscope Sidebar |
title=Tektronix P6201 |
summary= 900 MHz  active FET probe |
image=P6201_kit_new.JPG |
caption=Tektronix P6201 kit |
introduced=1973 |
discontinued= ?|
manuals=
* [http://w140.com/tek_p6201.pdf Tektronix P6201 Manual (PDF)]
}}
 
 
The '''Tektronix P6201''' is an active 900 MHz × 1 FET probe.   
The '''Tektronix P6201''' is an active 900 MHz × 1 FET probe.   


It can be powered from 7000 series mainframes having [[LEMO S-series connector]]s for probe power, or compatible units such as the [[1101]].
It can be powered from 7000 series mainframes having [[LEMO S-series connector]]s for probe power, or compatible units such as the [[1101]]. The probe has a [[BNC_connector_with_readout_ring|readout pin]] and the attenuation of the supplied attenuator plug-on tips is accurately encoded.


{{BeginSpecs}}
{{BeginSpecs}}
Line 13: Line 24:
{{Spec | Intended for | [[7000 series scopes]], [[485]], [[475]] }}
{{Spec | Intended for | [[7000 series scopes]], [[485]], [[475]] }}
{{EndSpecs}}
{{EndSpecs}}
==Manual==
* [http://w140.com/tek_p6201.pdf Tektronix P6201 Manual (PDF)]
==Pictures ==
==Pictures ==
<gallery>
<gallery>
Line 26: Line 33:
Lemo connector.jpg    |Lemo connector
Lemo connector.jpg    |Lemo connector
P6201 output box.jpg
P6201 output box.jpg
Tek_P6201-1.jpg
Tek_P6201-2.jpg
Tek_P6201-3.jpg
</gallery>
</gallery>
 
[[Category:Active oscilloscope probes]]
 
 
[[Category:Active Oscilloscope Probes]]

Revision as of 12:04, 4 July 2020

{{{manufacturer}}} 
900 MHz active FET probe
Tektronix P6201 kit

Produced from 1973 to ?

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix P6201 is an active 900 MHz × 1 FET probe.

It can be powered from 7000 series mainframes having LEMO S-series connectors for probe power, or compatible units such as the 1101. The probe has a readout pin and the attenuation of the supplied attenuator plug-on tips is accurately encoded.

Key Specifications

Bandwidth 900 MHz
Rise time 0.39 ns max.
Attenuation × 1, optional × 10 and × 100 plug-on tips (010-0376-00, 010-0377-00)
Dynamic range ±0.6 V with ±5.6 V DC offset (× 1), ±6 V with ±56 V DC offset (× 10), ±60 V with ±200 V DC offset (× 100)
Input impedance 100 kΩ // 3 pF (× 1), 1 MΩ // 1.5 pF (× 10/100)
Output impedance 25 Ω (with internal termination selected)
Intended for 7000 series scopes, 485, 475

Pictures