P6201: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 25: Line 25:
{{Spec | Dynamic range | ±0.6 V with ±5.6 V DC offset (× 1), ±6 V with ±56 V DC offset (× 10), ±60 V with ±200 V DC offset (× 100) }}
{{Spec | Dynamic range | ±0.6 V with ±5.6 V DC offset (× 1), ±6 V with ±56 V DC offset (× 10), ±60 V with ±200 V DC offset (× 100) }}
{{Spec | Input impedance | 100 kΩ // 3 pF (× 1), 1 MΩ // 1.5 pF (× 10/100) }}
{{Spec | Input impedance | 100 kΩ // 3 pF (× 1), 1 MΩ // 1.5 pF (× 10/100) }}
{{Spec | Output impedance | 25 Ω (with internal termination selected) }}
{{Spec | Output impedance |50 Ω (25 Ω with internal termination selected) }}
{{Spec | Intended for | [[7000 series scopes]], [[485]], [[475]] }}
{{Spec | Intended for | [[7000 series scopes]], [[485]], [[475]] }}
{{EndSpecs}}
{{EndSpecs}}

Revision as of 05:55, 25 July 2022

Tektronix P6201
900 MHz active FET probe
Tektronix P6201 kit

Compatible with 50 Ω scope inputs

Produced from 1973 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6201 is an active 900 MHz ×1 FET probe.

It can be powered from 7000 series mainframes having LEMO S-series connectors for probe power, or compatible units such as the 1101.

The probe has a readout pin and the attenuation of the supplied attenuator plug-on tips is accurately encoded.

Key Specifications

Bandwidth 900 MHz
Rise time 0.39 ns max.
Attenuation × 1, optional × 10 and × 100 plug-on tips (010-0376-00, 010-0377-00)
Dynamic range ±0.6 V with ±5.6 V DC offset (× 1), ±6 V with ±56 V DC offset (× 10), ±60 V with ±200 V DC offset (× 100)
Input impedance 100 kΩ // 3 pF (× 1), 1 MΩ // 1.5 pF (× 10/100)
Output impedance 50 Ω (25 Ω with internal termination selected)
Intended for 7000 series scopes, 485, 475

Pictures