P6420: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 9: | Line 9: | ||
{{Spec | Voltage Range | 0.5 to 24 V<sub>RMS</sub> (70 V<sub>p-p</sub>) }} | {{Spec | Voltage Range | 0.5 to 24 V<sub>RMS</sub> (70 V<sub>p-p</sub>) }} | ||
{{Spec | AC to DC Transfer Ratio Accuracy | ±10% from 0.5 to 5 V<sub>RMS</sub> between +15 and 35 °C }} | {{Spec | AC to DC Transfer Ratio Accuracy | ±10% from 0.5 to 5 V<sub>RMS</sub> between +15 and 35 °C }} | ||
{{Spec | Input Capacitance | | {{Spec | Input Capacitance | 3.7 pF }} | ||
{{Spec | Maximum Input Voltage | 42.4 V (peak AC + DC) }} | {{Spec | Maximum Input Voltage | 42.4 V (peak AC + DC) }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Datasheet== | |||
* [[Media:062-2764-00.pdf|Tektronix P6420 Datasheet (PDF)]] | |||
==Links== | ==Links== |
Revision as of 20:30, 29 February 2020
The Tektronix P6420 is an RF demodulator probe for DMMs with 10 MΩ input resistance, providing a DC output voltage proportional to the RMS value of a sine-wave input.
Designed to be used with a digital multimeter with a 10 MΩ input resistance, the P6420 can also be used with oscilloscopes which have a 1 MΩ input for relative flatness readings.
Key Specifications
Frequency range | 10 kHz to 1 GHz (±3 dB), 50 kHz to 500 MHz (±1.5 dB), 100 kHz to 300 MHz (±0.5 dB) |
---|---|
Voltage Range | 0.5 to 24 VRMS (70 Vp-p) |
AC to DC Transfer Ratio Accuracy | ±10% from 0.5 to 5 VRMS between +15 and 35 °C |
Input Capacitance | 3.7 pF |
Maximum Input Voltage | 42.4 V (peak AC + DC) |