RG501: Difference between revisions

169 bytes added ,  10 February 2022
Added service note
No edit summary
(Added service note)
Line 21: Line 21:
==Internals==
==Internals==
The RG501 uses Tek custom ICs [[155-0056-00]] (sweep control) and [[155-0042-03]] (Miller integrator).
The RG501 uses Tek custom ICs [[155-0056-00]] (sweep control) and [[155-0042-03]] (Miller integrator).
==Service Notes==
If Line Trigger is OK but the power supplies load down in other trigger modes, suspect Q15 is installed incorrectly because of different case styles.


==Links==
==Links==
1,330

edits