S-6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added link to local copy of instruction manual)
m (fixed broken link)
Line 35: Line 35:


* [http://jeroen.web.cern.ch/jeroen/S6/S6.shtml S-6 internal photo and simulation]
* [http://jeroen.web.cern.ch/jeroen/S6/S6.shtml S-6 internal photo and simulation]
* [https://www.circuitsathome.com/measurements/repairing-tektronix-s-6-sampling-head Repairing an S-6 head] (with internal photos)
* [https://chome.nerpa.tech/measurements/repairing-tektronix-s-6-sampling-head/ Repairing an S-6 head] (with internal photos)
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/7S12.htm S-6 @ amplifier.cd 7S12 page]
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/7S12.htm S-6 @ amplifier.cd 7S12 page]
* [http://www.barrytech.com/tektronix/tek7000/teks6.html S-6 @ barrytech.com]
* [http://www.barrytech.com/tektronix/tek7000/teks6.html S-6 @ barrytech.com]

Revision as of 22:34, 24 February 2021

Template:Plugin Sidebar 2 The Tektronix S-6 Sampling Head plug-in is a 50 Ω feed-through unit with a rise-time of 30 ps and bandwidth of 11.5 GHz. It was introduced in 1971.

The S-6 provides two unterminated 50 Ω SMA connections in a loop-through configuration as is convenient for TDR applications. It is good practice to leave a termination resistor on the unit when unused to give some protection against electrostatic discharge.

Key Specifications

Rise time 30 ps
Bandwidth 11.5 GHz
Operating input voltage range 1 Vp-p
Maximum single sample step 250 mV for less than 5% aberration
Maximum input voltage ±5 VDC
Input impedance 50 Ω (unterminated!)
Noise < 5 mV of noise
Features
  • No internal trigger pick-off signal
  • No internal termination

Links

Pictures

Measurements