The '''Tektronix TDS5034''' is a 350 MHz, 5 GS/s "digital phosphor" DSO.
{{Oscilloscope Sidebar |manufacturer=Tektronix |series=TDS series scopes|designers= |
model= TDS5034 |
summary=Digital Storage 350 MHz 4-channel scope |
image= Tek tds5034b 1.jpg |
caption=Tektronix TDS5034 |
introduced=2004 |
discontinued=(?) |
manuals=
* [[Media: 55W_14869_15_TDS5000_Series_DPO_Datasheet.pdf| TDS 5000 Series DPO Datasheet]] (743 KB, PDF)
* [[Media: 071-0876-02_TDS5000_Series_DPO_User_Manual.pdf| TDS5000 Series DPO User Manual]] (5.9 MB, PDF)
* [[Media: 071-1003-00_TDS5104,_TDS5054,_TDS5052_Read_This_First_Manual.pdf| TDS5000 Read This First Manual]] (1.1 MB, PDF)
* [[Media: 071-1004-02_TDS5000_Series_DPO_Service_Manual.pdf| TDS5000 Series DPO Service Manual]] (3.6 MB, PDF)
* [[Media: 071-1316-00_TDS5032_&_TDS5034_Supplement_Manual.pdf| TDS5032 & TDS5034 Supplement Manual]] (144 KB, PDF)
}}


==Manuals==
The '''Tektronix TDS5034''' is a four-channel, 350 MHz, 5 GS/s digital phosphor oscilloscope with a 10.4 in. LCD active-matrix color display.  This series of scopes combines 100,000 wfms/s continuous waveform capture rate and real-time intensity grading.  An optional touch screen was available for all models but was standard on the TDS5054B and TDS5104B.  The operating system is Windows 2000.
* [http://w140.com/service-manual-tds5034b-tds5054b-tds5104b.pdf Tektronix TDS5000B Series Service Manual (PDF)]
 
Besides the channel inputs, the AUX IN (auxiliary trigger), and [[Floppy]] drive, the left side panel has two [[USB connector]]s, two PS-2 ports (keyboard, mouse), two [[VGA Connector]], one [[Parallel printer interface]], [[GPIB]], [[Ethernet]] (RJ-45), [[RS-232 interface]], line out, line in, and microphone in, and a CD-ROM drive (Opt 16 replaces it with a CD-RW drive).  The rear panel has an EXT REF (time base reference) input, and AUX OUT (auxiliary trigger pulse output).
 
Applications modes available are FastAcq Acquisition (optimizes the instrument for analysis of dynamic signals and capture of infrequent events), Sample, Peak Detect (captures narrow glitches <1 ns at all real-time sample rates), Averaging (from 2 to 10,000 waveforms included in average), Envelope (from 2 to 10,000 waveforms included in min-max envelope), Hi-Res (real-time boxcar averaging reduces random noise and increases resolution), Waveform Database (accumulates a waveform database that provides a three-dimensional array of amplitude, time, and counts), and FastFrame Acquisition (acquisition memory divided into segments, maximum trigger rate >100,000 waveforms per second). 
 
There are many options for signal acquisition, measurement, and analysis.  The Overview section of the user manual is a great place to become familiar with the many functions available in the use of this sophisticated instrument.
 
{{BeginSpecs}}
{{Spec | Bandwidth and Channels| 350 MHz; bandwidth limit switchable between 20 MHz and 150 MHz; 4 channels }}
{{Spec | Vertical Sensitivity| 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) }}
{{Spec | Time Base Range| 200 ps to 40 s/div, 200 ps to 1000 s/div (B series) }}
{{Spec | Sample Rate (Max)| 5 GS/s on 1 channel, 2.5 GS/s on 2 channels, 1.25 GS/s on 3-4 channels }}
{{Spec | Max Record Length per channel|
* Std: 400 k (1 ch), 200 k (2 ch) , 100 k (4 ch);
* Opt 1M: 2 M (1 ch), 1 M (2 ch), 500 k (4 ch);
* Opt 2M: 8 M (1 ch), 4 M (2 ch), 2 M (4 ch) }}
{{Spec | Max Record Length per channel (B series)|
* Std (TDS5034B): 8 M (1 ch), 4 M (2 ch), 2M (4 ch);
* Opt 3M (TDS5034B): 16 M (1 ch), 8 M (2 ch) , 4 M (4 ch) }}
{{Spec | Waveform Measurements| Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians }}
{{Spec | Probes| Four [[P5050]] 500 MHz ×10 probes, [[BNC connector]] with a [[readout pin]] }}
{{Spec | Power| 100 − 240 V<sub>AC</sub>, 47 − 63 Hz, CAT II, <220 W }}
 
{{EndSpecs}}


==Pictures==
==Pictures==

Latest revision as of 08:49, 11 August 2021

Tektronix TDS5034
Digital Storage 350 MHz 4-channel scope
Tektronix TDS5034

Produced from 2004 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix TDS5034 is a four-channel, 350 MHz, 5 GS/s digital phosphor oscilloscope with a 10.4 in. LCD active-matrix color display. This series of scopes combines 100,000 wfms/s continuous waveform capture rate and real-time intensity grading. An optional touch screen was available for all models but was standard on the TDS5054B and TDS5104B. The operating system is Windows 2000.

Besides the channel inputs, the AUX IN (auxiliary trigger), and Floppy drive, the left side panel has two USB connectors, two PS-2 ports (keyboard, mouse), two VGA Connector, one Parallel printer interface, GPIB, Ethernet (RJ-45), RS-232 interface, line out, line in, and microphone in, and a CD-ROM drive (Opt 16 replaces it with a CD-RW drive). The rear panel has an EXT REF (time base reference) input, and AUX OUT (auxiliary trigger pulse output).

Applications modes available are FastAcq Acquisition (optimizes the instrument for analysis of dynamic signals and capture of infrequent events), Sample, Peak Detect (captures narrow glitches <1 ns at all real-time sample rates), Averaging (from 2 to 10,000 waveforms included in average), Envelope (from 2 to 10,000 waveforms included in min-max envelope), Hi-Res (real-time boxcar averaging reduces random noise and increases resolution), Waveform Database (accumulates a waveform database that provides a three-dimensional array of amplitude, time, and counts), and FastFrame Acquisition (acquisition memory divided into segments, maximum trigger rate >100,000 waveforms per second).

There are many options for signal acquisition, measurement, and analysis. The Overview section of the user manual is a great place to become familiar with the many functions available in the use of this sophisticated instrument.

Key Specifications

Bandwidth and Channels 350 MHz; bandwidth limit switchable between 20 MHz and 150 MHz; 4 channels
Vertical Sensitivity 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω)
Time Base Range 200 ps to 40 s/div, 200 ps to 1000 s/div (B series)
Sample Rate (Max) 5 GS/s on 1 channel, 2.5 GS/s on 2 channels, 1.25 GS/s on 3-4 channels
Max Record Length per channel
  • Std: 400 k (1 ch), 200 k (2 ch) , 100 k (4 ch);
  • Opt 1M: 2 M (1 ch), 1 M (2 ch), 500 k (4 ch);
  • Opt 2M: 8 M (1 ch), 4 M (2 ch), 2 M (4 ch)
Max Record Length per channel (B series)
  • Std (TDS5034B): 8 M (1 ch), 4 M (2 ch), 2M (4 ch);
  • Opt 3M (TDS5034B): 16 M (1 ch), 8 M (2 ch) , 4 M (4 ch)
Waveform Measurements Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians
Probes Four P5050 500 MHz ×10 probes, BNC connector with a readout pin
Power 100 − 240 VAC, 47 − 63 Hz, CAT II, <220 W