TDS620: Difference between revisions

1,677 bytes added ,  25 November 2021
Added information
(Added firmware TDS620B v4.2e and links.)
(Added information)
Line 85: Line 85:
==Firmware==
==Firmware==
* [[Media:TDS620B v4.2e Firmware.zip|TDS620B v4.2e Firmware]] (ZIP)
* [[Media:TDS620B v4.2e Firmware.zip|TDS620B v4.2e Firmware]] (ZIP)
==Options==
* 05 - Video Trigger                              - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
* 1M - 4M acquisition length                      - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
* 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
* 1F - Floppy disk drive                          - Add 3.5 inch, 1.44 MByte floppy disc drive.
* 2F - Advanced DSP math                          - Add advanced DSP math features such as FFT, integration, and differentiation.
==Optional Accessories==
* 1K - Add K420 scope cart
* 1R - Rackmount kit
* 2D - Delete standard 2 P6205 probes
* 22 - (TDS620A) Add 2 each P6139A passive probes
* 23 - (TDS620A) Add 4 each P6245 active FET probes
* 24 - (TDS620B) Add 4 each P6139A passive probes
* D1 - Calibration data report
==TDS620A Included Accessories==
* 2x P6205 FET Probes
* 070-8711-02 - Reference Manual
* 070-8711-01 - User Manual
* 200-3696-01 - Front cover
* 161-0230-01 - US power cord
==TDS620B Included Accessories==
* 2x P6139A FET Probes
* 070-9382-00 - Quick Reference Guide
* 070-6869-00 - User Manual
* 070-9874-02 - Technical Reference Manual
* 200-3696-01 - Front cover
* 161-0230-01 - US power cord
==Recommended Accessories==
* 012-0991-01 - 1m GPIB cable
* 012-0991-00 - 2m GPIB cable
* 012-1298-00 - RS-232 cable
* 012-1250-00 - Centronics cable
* 016-0909-01 - Soft-sided carrying case
* 016-01135-00 - Transit case
* K420 - Scope cart


==Links==