TDS744A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added schematics)
(Added manuals and software)
Line 10: Line 10:
|designers=
|designers=
|manuals=
|manuals=
==Common==
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]]
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]]
* [[Media:070-8709-07.pdf|TDS400A/500A/600A/700A Programmer 070-8709-07]]
* [[Media:070-8709-07.pdf|TDS400A/500A/600A/700A Programmer 070-8709-07]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface 070-8709-02]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]]
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]]
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]]
* [[Media:070-8990-04.pdf|TDS684A/744A/784A Performance Verification and Specifications 070-8990-04]]
* [[Media:070-8991-02.pdf|TDS684A/744A/784A User 070-8991-02]] / <small>[[Media:070-8991-02 c2.pdf|Alternate copy]]</small>
* [[Media:070-8992-02.pdf|Tektronix TDS 684A and TDS 744 Service Manual (November 1994, PDF)]]
* [[Media:070-8992-03.pdf|TDS684A/744A/784A Service 070-8992-03]]
* [[Media:070-8999-02.pdf|TDS684A/744A/784A Reference 070-8999-02]] / <small>[[Media:070-8999-02 c2.pdf|Alternate copy]]</small>
* [[Media:070-9382-01.pdf|TDS500B/600B/700A Reference 070-9382-01]]
* [[Media:070-9384-01.pdf|TDS500B/600B/700A Performance Verification and Specifications 070-9384-01]]
* [[Media:070-9386-03.pdf|TDS500B/500B/700A Service 070-9386-03]]
* [[Media:070-9473-01.pdf|TDS684A/744A/784A Firmware Field Upgrade 070-9473-01]]
* [[Media:070-9473-01.pdf|TDS684A/744A/784A Firmware Field Upgrade 070-9473-01]]
* [[Media:070-9636-02.pdf|TDS Family Opt 05 Video Trigger Interface Install 070-9636-02]]
* [[Media:070-9636-02.pdf|TDS Family Opt 05 Video Trigger Interface Install 070-9636-02]]
* [[Media:070-9719-00.pdf|TDS500B/600B/700A Digitizing Oscilloscopes 070-9719-00]]
* [[Media:070-9721-02.pdf|TDS500B/600B/700A Service Manual 070-9721-02]]
* [[Media:070-9785-03.pdf|Wavestar Software User Manual 070-9785-03]]
* [[Media:070-9785-03.pdf|Wavestar Software User Manual 070-9785-03]]
* [[Media:071-0220-07.pdf|WSTRO & WSTROU WaveStar Software User Manual 071-0220-07]]
* [[Media:071-0220-07.pdf|WSTRO & WSTROU WaveStar Software User Manual 071-0220-07]]
Line 35: Line 26:
* [[Media:071-0817-00.pdf|WSTRO, WSTROU & WSTRM WaveStar Software, AD007 GPIB-LAN Adapter, TDS3EM Ethernet Comms Module User Manual 071-0817-00]]
* [[Media:071-0817-00.pdf|WSTRO, WSTROU & WSTRM WaveStar Software, AD007 GPIB-LAN Adapter, TDS3EM Ethernet Comms Module User Manual 071-0817-00]]
* [[Media:071-1140-03.pdf|WaveStar Software, Wavestar Reader, AD007 GPIB-LAN Adapter Software Solutions Installation 071-1140-03]]
* [[Media:071-1140-03.pdf|WaveStar Software, Wavestar Reader, AD007 GPIB-LAN Adapter Software Solutions Installation 071-1140-03]]
* [[Media:Tek_TDS744A_DRAM_Processor_Display_Module_Schematic.pdf|DRAM Processor Display Module Schematic]]
 
==TDS744==
* [[Media:070-8991-01.pdf|TDS744 User Manual 070-8991-01]]
* [[Media:070-8992-02.pdf|TDS744 Service Manual 070-8992-02]]
 
==TDS744A==
* [[Media:070-8990-04.pdf|TDS744A Performance Verification and Specifications 070-8990-04]]
* [[Media:070-8991-02.pdf|TDS744A User Manual 070-8991-02]] / <small>[[Media:070-8991-02 c2.pdf|Alternate copy]]</small>
* [[Media:070-8992-03.pdf|TDS744A Service Manual 070-8992-03]]
* [[Media:070-8999-02.pdf|TDS744A Reference 070-8999-02]] / <small>[[Media:070-8999-02 c2.pdf|Alternate copy]]</small>
* [[Media:070-9382-01.pdf|TDS700A Reference 070-9382-01]]
* [[Media:070-9384-01.pdf|TDS744A Performance Verification and Specifications 070-9384-01]]
* [[Media:070-9386-03.pdf|TDS744A Service Manual 070-9386-03]]
* [[Media:070-9702-00.pdf|TDS744A Programmer Manual 070-9702-00]]
* [[Media:070-9719-00.pdf|TDS700A Digitizing Oscilloscopes 070-9719-00]]
* [[Media:070-9721-02.pdf|TDS700A Service Manual 070-9721-02]]
 
==Schematics==
* [[Media:Tek_TDS744A_DRAM_Processor_Display_Module_Schematic.pdf|TDS744A DRAM/Processor/Display Module Schematic]]
 
}}
}}
The '''TDS744''' is a 500 MHz, 2 GS/s four-channel digital scope with a color screen.
The '''TDS744''' is a 500 MHz, 2 GS/s four-channel digital scope with a color screen.
Line 53: Line 63:


==Software==
==Software==
* [[Media:TDS700A_Field_Adjustment_Software_PN_063260100.zip|TDS700A Field Adjustment Software 063260100]] (ZIP)
* [[Media:TDS700A_Field_Adjustment_Software_PN_063260100.zip|TDS700A Field Adjustment Software 063-2601-00]] (ZIP)
* [[Media:TDS300-400-500-600-700-800_AWE_Drivers_066008700.zip|Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066008700]] (ZIP)
<br>
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN]] (ZIP, 102MB) ''Product Key: WSTRO618650124''
* [[Media:TDS300-400-500-600-700-800_AWE_Drivers_066008700.zip|Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066-0087-00]] (ZIP)
* [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP]] (ZIP)
* [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP 066-0119-00]] (ZIP)
* [[Media:066-0201-00.zip|Telecommunications Option for TDS Oscilloscopes 066-0201-00]] (ZIP)
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP)
* [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP)
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124''


==Firmware==
==Firmware==
* [[Media:TDS744A_v1.0e_Firmware.zip|TDS744A v1.0e Firmware]] (ZIP)
* [[Media:TDS744A_v1.0e_Firmware.zip|TDS744A v1.0e Firmware]] (ZIP)
* [http://www.ko4bb.com/getsimple/index.php?id=download&file=Tektronix/Tektronix_-_744A_Oscilloscope/Tektronix_744A_Oscilloscope_EPROM_v1.1E.BIN TDS744A v1.1E Firmware @ KO4BB]
* [[Media:TDS744A_v1.1e_Firmware.zip|TDS744A v1.1e Firmware]] (ZIP)
* [[Media:TDS744A_v4.2.1e_Firmware.zip|TDS744A v4.2.1e Firmware]] (ZIP)
* [[Media:TDS744A_v4.2.1e_Firmware.zip|TDS744A v4.2.1e Firmware]] (ZIP)



Revision as of 08:18, 25 April 2022

Tektronix TDS744A
4-ch 500 MHz, 2 GS/s digital scope
Tektronix TDS744A

Produced from 1995 to 1998?

Manuals

Common

TDS744

TDS744A

Schematics

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The TDS744 is a 500 MHz, 2 GS/s four-channel digital scope with a color screen.

Key Specifications

Bandwidth 500 MHz at 10 mv/div and above; 500 MHz @ 5 mV/div; 500 MHz @ 2 mV/div; 450 MHz @ 1 mV/div
Sample rate 1 channel @ 2 GS/s, 2 channels @ 1 GS/s, 3 or 4 channels @ 500 MS/s
Resolution 8 bit
Record length 50k samples per channel (500k with option 1M)
Acquisition modes sample, envelope, average, high-resolution, peak-detect
Display Color; Zoom
Trigger modes Edge, logic, pulse; Video trigger with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat)
Storage 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive
I/O Full GPIB programmability
Hardcopy Using GPIB, RS-232, or Centronics ports

Software


Firmware

Options

  • 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
  • 1M - 4M acquisition length - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
  • 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
  • 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive.
  • 2F - Advanced DSP math - Add advanced DSP math features such as FFT, integration, and differentiation.
  • 2C - Communication Signal Analyzer - Oscilloscope comes configured for communications signal triggering and mask testing.
  • 3C - P6701B with system calibration - Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference receiver on channel 1.
  • 4C - P6703B with system calibration - Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference receiver on channel 1.
  • 2M - 8M acquisition length - TDS 520D, 724D: To 2M samples on two channels and 4M on one channel. TDS 540D, 580D, 714L, 754D, 784D, 794D: To 2M samples on three or four channels, 4M on two channels, and 8M samples on one channel (Option includes a hard disk and is only available for the models listed above.)

Links

Pictures

Internals