Z: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(ten-turn pot, disconnect buttons)
mNo edit summary
(32 intermediate revisions by 6 users not shown)
Line 1: Line 1:
The Tektronix Type Z is a comparator plug-in for [[500-series scopes]].
{{Plugin Sidebar 2|
Its maximum sensitivity is 50mV/div, and it achieves 40,000 to 1 common-mode
title=Tektronix Type Z|
rejection at DC and low frequencies. Its risetime as a general-purpose
summary=Comparator preamp plug-in|
amplifier is 27ns (13MHz bandwidth), but it can track a common-mode risetime of 7ns.
image=Tek z front.jpg |
caption=Type Z front view|
introduced=1960 |
discontinued=1969 |
series=[[500-series scopes]]|
manuals=
* [[Media:070-251.pdf|Tektronix Type Z Manual]] (PDF, OCR)
* [[Media:tek_type_z_fcp.pdf|Tektronix Type Z Factory Calibration Procedure (PDF)]]
}}
The '''Tektronix Type Z''' is a comparator plug-in for [[500-series scopes]], [[introduced in 1960]] and dropped after 1968.


Type Z has two inputs, A and B, plus a precision comparison voltage, Vc, that is
The Type Z has two inputs, A and B, plus a precision comparison voltage, V<sub>C</sub>, that is
adjustable from 0 to +/-1V, 10V, or 100V via a ten-turn pot.  It's possible to
adjustable from 0 to ±1 V, 10 V, or 100 V via a ten-turn pot.   
view A, -B, A-B, A-Vc, or Vc-B.


Unlike later comparators, it has a separate step attenuator for each input,
The following differential amplifier can be configured to display V<sub>A</sub>, −V<sub>B</sub>,  
permitting you to view the difference between signals of widely differing amplitudes.
V<sub>A</sub>−V<sub>B</sub>, V<sub>A</sub>−V<sub>C</sub>, or V<sub>C</sub>−V<sub>B</sub>.
It is also the only comparator that can handle +/- 100V common mode at full sensitivity.


With a pair of "Disconnect Signal" buttons, Type Z was the first movement toward a "Gnd"
This allows DC-coupled measurements of small signals with large DC offsets.
position on the input switches.


The Type [[P6023]] probe, with R and C compensation, was specifically designed for Type Z.
Unlike later comparators, Type Z has separate step attenuators for each input,
permitting the user to view the difference between signals of widely differing amplitudes.


Type Z was introduced between 1960 and 1962 and uses both tubes and transistors,
It is also the only comparator that can handle ±100 V common mode at full sensitivity.
capitalizing on each's strengths.


* http://bama.edebris.com/manuals/tek/z/
With a pair of "Disconnect Signal" buttons, the Type Z was the first
* http://w140.com/tek_fcp/tek_type_z_factory_cal_proc.pdf
movement toward a "GND" position on the input switches.
 
The Type [[P6023]] probe with R and C compensation, [[introduced in 1962]],
was specifically designed for the Type Z but also marketed for the Type [[G]].
 
==Specifications==
Maximum sensitivity is 50 mV/div, and common-mode rejection at DC and low frequencies is 40,000 to 1.
 
Risetime as a general-purpose amplifier is 27 ns (13 MHz bandwidth), but it can track a common-mode risetime of 7 ns.
 
[[Category:Specifications needed]]
 
==Internals==
The Type Z uses both tubes and transistors, capitalizing on the strengths of each. 
 
The step attenuators are [[turret attenuators]].
 
==Links==
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/Z.html Type Z @ amplifier.cd]
 
==Pictures==
 
<gallery>
Tek z front.jpg|3/4 View
Tek z 1.jpg| Front View
Tek z 7.jpg | Front View
Tek type z pre-prod.jpg|Pre-production Type Z with different knob color
Tek z left.jpg|Left Side
Tek z 5.jpg | Left Side
Tek_TypeZ-RHS.jpeg | Right Side
Tek z 2.jpg | Right Side
Tek z 3.jpg | Right Side
Tek z 6.jpg | Right Side  Tubes
Tek_TypeZ-Top.jpeg  | Top
Tek z 4.jpg | Rear
</gallery>
 
==Schematic==
<gallery>
Tek_z_turret.png|Attenuators
Tek_z_schem.png|Main Amplifier
</gallery>
 
[[Category:500 series plugins]]
[[Category:Differential amplifiers]]

Revision as of 18:40, 22 February 2021

Template:Plugin Sidebar 2 The Tektronix Type Z is a comparator plug-in for 500-series scopes, introduced in 1960 and dropped after 1968.

The Type Z has two inputs, A and B, plus a precision comparison voltage, VC, that is adjustable from 0 to ±1 V, 10 V, or 100 V via a ten-turn pot.

The following differential amplifier can be configured to display VA, −VB, VA−VB, VA−VC, or VC−VB.

This allows DC-coupled measurements of small signals with large DC offsets.

Unlike later comparators, Type Z has separate step attenuators for each input, permitting the user to view the difference between signals of widely differing amplitudes.

It is also the only comparator that can handle ±100 V common mode at full sensitivity.

With a pair of "Disconnect Signal" buttons, the Type Z was the first movement toward a "GND" position on the input switches.

The Type P6023 probe with R and C compensation, introduced in 1962, was specifically designed for the Type Z but also marketed for the Type G.

Specifications

Maximum sensitivity is 50 mV/div, and common-mode rejection at DC and low frequencies is 40,000 to 1.

Risetime as a general-purpose amplifier is 27 ns (13 MHz bandwidth), but it can track a common-mode risetime of 7 ns.

Internals

The Type Z uses both tubes and transistors, capitalizing on the strengths of each.

The step attenuators are turret attenuators.

Links

Pictures

Schematic