File:L3 A125 atten cap replaced.jpg
Jump to navigation
Jump to search

Size of this preview: 800 × 475 pixels. Other resolutions: 2,560 × 1,519 pixels | 4,080 × 2,421 pixels.
Original file (4,080 × 2,421 pixels, file size: 835 KB, MIME type: image/jpeg)
Summary
This orange cap on the A125 attenuator board was the cause of the short between +15V and ground. Also note the pin connector to the left of K130: it appears fatigued; the wings that are supposed to hold the leaf spring in are cracked and bent out.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 22:27, 21 March 2025 | ![]() | 4,080 × 2,421 (835 KB) | Mark999 (talk | contribs) | This orange cap on the A125 attenuator board was the cause of the short between +15V and ground. |