==Wavy trace == | ==Wavy trace == | ||
:'''Symptom:''' Wavy trace | :'''Symptom:''' Wavy trace | ||
:'''Root cause:''' C786 ( | :'''Root cause:''' C786 (100 µF 25 V) has high internal resistance (ESR ~ 20 Ω) causing +12.6 V regulator circuit to oscillate | ||
:'''Solution:''' | :'''Solution:''' Replace C786 with new part. | ||
:<gallery> | :<gallery> | ||
585 wavy trace.JPG | wavy trace | 585 wavy trace.JPG | wavy trace | ||
585_wavy_trace_new_electrolytics.JPG | | 585_wavy_trace_new_electrolytics.JPG | +12.6 v PSU with new eletrolytics. | ||
</gallery> | </gallery> | ||
:--[[User:Matt|Matt]] ([[User talk:Matt|Matt]]) 08:53, 5 May 2019 (PDT) | :--[[User:Matt|Matt]] ([[User talk:Matt|Matt]]) 08:53, 5 May 2019 (PDT) |