157-0099-00 selection procedure exceeds tube max ratings!
m (not used in late W)
(157-0099-00 selection procedure exceeds tube max ratings!)
Line 7: Line 7:
Contrast this with another Nuvistor triode, the [[7586]],
Contrast this with another Nuvistor triode, the [[7586]],
which has a maximum plate-to-cathode voltage of 110 V.
which has a maximum plate-to-cathode voltage of 110 V.
(But note that one of the 8056 test conditions for 157-0099-00 puts 100V on the plate.)


The 7586 and 8056 have the same pinout,
The 7586 and 8056 have the same pinout,