Line 10: Line 10:
|designers=Cal Hongel;
|designers=Cal Hongel;
|manuals=
|manuals=
* [http://w140.com/tek_p6042.pdf Tektronix P6042 Manual (PDF)]
* [[Media:070-0629-00.pdf|Tektronix P6042 Manual]]
}}
}}
The '''Tektronix P6042''' is a DC to 50 MHz current probe [[introduced in 1967]].  It was designed by [[Cal Hongel]].
The '''Tektronix P6042''' is a DC to 50 MHz current probe [[introduced in 1967]].  It was designed by [[Cal Hongel]].
Line 33: Line 33:
The P6042's core halves are precision lapped and potted with epoxy.  They have Mu-metal screening.  The lower (fixed) core also contains the Hall element.  
The P6042's core halves are precision lapped and potted with epoxy.  They have Mu-metal screening.  The lower (fixed) core also contains the Hall element.  
Unfortunately, the P6042 probe is quite sensitive mechanically, and in many units offered for sale, the cores are damaged.
Unfortunately, the P6042 probe is quite sensitive mechanically, and in many units offered for sale, the cores are damaged.
The amplifier front-end is constructed using a 156-0014-00 differential amplifier integrated circuit, labelled "M18", which [[Media:Tektronix_Xref_sm.pdf|cross-references]] to a long-obsolete Teledyne "831-BE".  [[Jim Williams]]' [https://www.analog.com/media/en/technical-documentation/application-notes/an61fa.pdf Applicaion Note 61] contains a replacement circuit using LT1228 opamps.