The Tektronix Type CA is the most common plug-in for 500-series scopes. Over 50,000 were produced.

The risetime of a Type 545 oscilloscope with a Type CA plug-in is 15 nanoseconds, and the bandwidth is 24MHz. Maximum vertical sensitivity is 50mV/div.

Type CA is an enhancement over its predecessor, Type 53/54C, adding ADDED mode to the A, B, CHOPPED, ALT repertoire. The "A" in "CA" stands not only for the fact that it is a modified, enhanced replacement, but also because the feature added was ADDED. It was introduced in 1959 and discontinued in 1972 or 1973, making it not only the most-produced but also the longest-lived, if you include Type C.

Late versions have BNC connectors instead of UHF.