TDS5032: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "{{Oscilloscope Sidebar | title=Tektronix TDS5032 | summary=Digital Storage 350 MHz 2-channel scope | image= TDS5032_Waveform_image.jpg | caption=Tektronix TDS5032 | introduced...")
 
No edit summary
Line 26: Line 26:
{{Spec | Vertical Sensitivity| 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) }}
{{Spec | Vertical Sensitivity| 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) }}
{{Spec | Time Base Range| 200 ps to 1000 s/div }}
{{Spec | Time Base Range| 200 ps to 1000 s/div }}
{{Spec | Sample Rate (Max)| 5 GS/s on 1 channel, 2.5 GS/s on 2 channels, 1.25 GS/s on 3-4 channels }}  
{{Spec | Sample Rate (Max)| 5 GS/s on 1 channel, 2.5 GS/s on 2 channels }}  
{{Spec | Max Record Length per channel|  
{{Spec | Max Record Length per channel|  
Std mem: 400 k (1 ch), 200 k (2 ch) , 100 k (4 ch); Opt 1M mem: 2 M (1 ch), 1 M (2 ch), 500 k (4 ch); Opt 2M mem: 8 M (1 ch), 4 M (2 ch), 2 M (4 ch) }}
Std mem: 400 k (1 ch), 200 k (2 ch); Opt 1M mem: 2 M (1 ch), 1 M (2 ch); Opt 2M mem: 8 M (1 ch), 4 M (2 ch) }}
{{Spec | Max Record Length per channel (B series)|
Std mem (TDS5034B): 8 M (1 ch), 4 M (2 ch), 2M (4 ch); Std mem (TDS5054B/TDS5104B): 16 M (1 ch), 8 M (2 ch) , 4 M (4 ch); Opt 3M mem (TDS5034B): 16 M (1 ch), 8 M (2 ch) , 4 M (4 ch); Opt 3M mem (TDS5054B/TDS5104B): NA }}
{{Spec | Waveform Measurements| Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians }}
{{Spec | Waveform Measurements| Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians }}
{{Spec |  
{{Spec |  
Line 45: Line 43:




[[Category:TDS3000 series scopes]]
[[Category:TDS5000 series scopes]]

Revision as of 09:40, 9 June 2019

{{{manufacturer}}} 
Digital Storage 350 MHz 2-channel scope
Tektronix TDS5032

Produced from  ? to ?

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix TDS3054 is a two-channel, 350 MHz, 5 GS/s digital phosphor oscilloscope with a 10.4 in. LCD active-matrix color display. This series of scopes combines 100,000 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it. An optional touch screen was available for all models but was standard on the TDS5054B and TDS5104B. The operating system is Windows 2000.

Besides the channel inputs, the AUX IN (auxiliary trigger), and Floppy drive, the Left Side panel has two USB ports, two PS-2 ports (Keyboard, Mouse), two VGA connectors, one Parallel port, GPIB, RJ-45, Serial port, line out, line in, and microphone in, and a CD-ROM drive (Opt 16 replaces it with a CD-RW drive), and the Rear panel has a EXT REF (time base reference input), AUX OUT (auxiliary trigger pulse output), and SIGNAL OUT (buffered CH 3 signal on the TDS5054 and TDS5104 only).

Applications Modes available are FastAcq Acquisition (optimizes the instrument for analysis of dynamic signals and capture of infrequent events), Sample, Peak Detect (captures narrow glitches <1 ns at all real-time sample rates), Averaging (from 2 to 10,000 waveforms included in average), Envelope (from 2 to 10,000 waveforms included in min-max envelope), Hi-Res (real-time boxcar averaging reduces random noise and increases resolution), Waveform Database (accumulates a waveform database that provides a three-dimensional array of amplitude, time, and counts), and FastFrame Acquisition (acquisition memory divided into segments, maximum trigger rate >100,000 waveforms per second).

There are many options for signal acquisition, measurement, and analysis. The Overview section of the User Manual is a great place to become familiar with the many functions available in the use of this sophisticated instrument.

Key Specifications

{{Spec |
Bandwidth and Channels 350 MHz; Bandwidth Limit switchable between 20 MHz and 150 MHz; 2 Channels
Vertical Sensitivity 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω)
Time Base Range 200 ps to 1000 s/div
Sample Rate (Max) 5 GS/s on 1 channel, 2.5 GS/s on 2 channels
Max Record Length per channel

Std mem: 400 k (1 ch), 200 k (2 ch); Opt 1M mem: 2 M (1 ch), 1 M (2 ch); Opt 2M mem: 8 M (1 ch), 4 M (2 ch)

Waveform Measurements Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians

Pictures