The '''Tektronix 2710''' is a spectrum analyzer [[introduced in 1986]] that covers the frequency range from 10 kHz to 1.8 GHz.
{{Oscilloscope Sidebar |
title=Tektronix 2710 |
summary=Spectrum Analyzer 10 kHz to 1.8 GHz |
image= Tek_2710_Waveform_image.jpg |
caption=Tektronix 2710 |
introduced=1987 |
discontinued=1993 |
manuals=
Need Operator’s and Service Manuals
* [[Media:tek_2710_operator.pdf| Tektronix 2710 Operators Manual (PDF, OCR)]]
* [[Media:Tektronix_2710_Spectrum_Analyser_Service_Manual.pdf| Tektronix 2710 Service Manual (PDF, OCR)]]
* [[Media: tek_2710_gpib_programmer.pdf| Tektronix 2710 GPIB Programmers Manual (PDF, OCR)]]
}}


{{MissingSpecs}}
The '''Tektronix 2710''' is a spectrum analyzer with a frequency range of 10 kHz to 1.8 GHz in coax.  The minimum resolution bandwidth is 3 kHz, and provides measurement resolution proportional to the frequency accuracy or span.   With non-volatile memory (NVRAM) at 28 kB can save up to 18 displays of waveforms and markers, and up to 9  front panel setups, large user-defined key programs, and antenna factor tables.
Minimum resolution bandwidth is 3 kHz. Minimum span is 10 kHz/div.


==Manuals==
The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace.  Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.


* [http://w140.com/tek_2710_operator.pdf Tektronix 2710 Operators Manual (PDF)]
True analog display capability, along with fast sweep speeds and TV Line and TV Field triggering provide demodulation of video carriers for making depth-of-modulation checks or looking at special baseband data, VITS, and other signals.  An internal audio amplifier and AM/FM detectors let one hear demodulated signals, using either the build-in speaker or headphone jace for signal identification and troubleshooting and in communications applications.
* [http://w140.com/Tektronix_2710_Spectrum_Analyser_Service_Manual.pdf Tektronix 2710 Service Manual (PDF)]
 
* [http://w140.com/tek_2710_gpib_programmer.pdf Tektronix 2710 GPIB Programming Manual (PDF)]
Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or Centronics interface via Opt. 09.
 
Front panel inputs/outputs are: RF INPUT [[N connector]] (50Ω, +20 dBm Max, 100 V DC blocking capacitor); and GEN [[N connector]] (50Ω, 0 to -48 dBm, Opt. 4 Tracking Generator generates a sweep frequency to enable the Spectrum Analyzer to make circuit response measurements, i.e. scalar network analysis).
 
Rear panel inputs/outputs are: J101 [[SMA connector]] (Female SMA installed for Opt. 15), J102 EXT TRIG [[BNC connector]] (10 kΩ, 35V (DC + peak AC)), J103 [[DB9 connector]] (Not RS-232 compatible.  Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 [[GPIB connector]] (Digital Communication Port.  IEEE Std 488 connector.)  .
 
{{BeginSpecs}}
{{Spec | Frequency Range | 10 kHz to 1.8 GHz }}
{{Spec | Frequency Span Range (plus 0 Hz and MAX: 180 MHz/div) | 10 kHz/div to 100 MHz/div in 1, 2, 5 sequence }}
{{Spec | Resolution Bandwidth Range | 6 dB bandwidth selections are 3 kHz, 30 kHz, 300 kHz, and 5 MHz ; Down to 300 Hz with Opt. 01}}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | Maximum Safe Input Power | +20 dBm (0.1W) continuous peak, ≤100 VDC
{{Spec | RF Attenuator Range | 0 dB to 50 dB, 2 dB steps }}
{{Spec | Sensitivity | -117 dBm at 3 kHz RBW, -129 dBm at 3 kHz RBW w/preamp }}
{{Spec | Reference Level Range | -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV }}
{{Spec | Sweep Speed Range | 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence }}
{{Spec | Triggering Modes | Free Run, Internal, External, Line, TV Line, and TV Field }}
{{Spec | Displayed Average Noise | −66 dBm to −100 dBm }}
{{Spec | Display Dynamic Range | 80 dB }}
{{Spec | Dynamic Range | ≥100 dBm }}
{{Spec | Internal Calibrator | 100 MHz marker at -30 dBm }}
{{Spec | Included Accessories | Operator’s Manual; Power Cord; Front Cover; Adapter 50 Ω N Male to BNC Female, Ω 75 to 50 Ω Minimum Loss Attenuator N Male to BNC Female }}
{{Spec | Weight | Standard accessories: 11.25 kg (<25 lbs); Basic configuration: 9.5 kg (<21 lbs) }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 440 Hz; 90 – 250 V<sub>AC</sub>, 47 to 63 Hz. At 115 V<sub>AC</sub>, 60 Hz, 90 W (standard), 105 W max (with options) }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C;  Humidity: MIL-Std-28800C class 5; Altitude: Up to 4.6 km (15,000 ft) }}
{{EndSpecs}}
 
==Options==
* Opt. 01: 300 Hz Resolution Bandwidth filter; Phase-lock with span/div ≤20 kHz
* Opt. 02: Frequency Counter, 1 Hz or 1 kHz, menu selectable
* Opt. 03: GPIB Interface (cannot be combined with Opt. 09)
* Opt. 04: TG Tracking Generator, 100 kHz to 1.8 GHz (cannot be combined with Opt. 14)
* Opt. 06: Battery Power Option (2704 Inverter and 2705 Battery Pack)
* Opt. 08: RS-232(D) (cannot be combined with Opt. 03)
* Opt. 09: Centronix interface (cannot be combined with Opt. 03)
* Opt. 10: Video Monitor mode
* Opt. 11: Non-volatile RAM storage for setups, displays, and user-definable key sequences
* Opt. 14: Adds Resolution Bandwidths of 1 kHz, 10 kHz, 100 kHz, and 1 MHz (cannot be combined with Opt. 04)
* Opt. 15: Tek 1405 TV Sideband Adapter interface installed at J101 as SMA female
* Opt. 30: Rackmount
* Opt. 33: Travel Line Package
* Opt. 34: Portable to Rackmount Adapter.
 
See also the [[2706|2706 preselector]] and [[2707|2707 tracking generator]].


==Pictures==
==Pictures==
<gallery>
<gallery>
2710.jpg
Tek_2710_Waveform_image.jpg
Tek 2710 front.jpg
Tek_2710_2.jpg
Tek_2710_3.jpg
Tek_2710_4.jpg
Tek_2710_5.jpg
Tek_2710_6.jpg
Tek_2710_7.jpg
Tek_2710_8.jpg
</gallery>
</gallery>


[[Category:Spectrum Analyzers]]
[[Category: Spectrum Analyzers]]
[[Category:GPIB interface]]
[[Category:Introduced in 1986]]

Revision as of 23:06, 29 June 2019

{{{manufacturer}}} 
Spectrum Analyzer 10 kHz to 1.8 GHz
Tektronix 2710

Produced from 1987 to 1993

Manuals

Need Operator’s and Service Manuals

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 2710 is a spectrum analyzer with a frequency range of 10 kHz to 1.8 GHz in coax. The minimum resolution bandwidth is 3 kHz, and provides measurement resolution proportional to the frequency accuracy or span. With non-volatile memory (NVRAM) at 28 kB can save up to 18 displays of waveforms and markers, and up to 9 front panel setups, large user-defined key programs, and antenna factor tables.

The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace. Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.

True analog display capability, along with fast sweep speeds and TV Line and TV Field triggering provide demodulation of video carriers for making depth-of-modulation checks or looking at special baseband data, VITS, and other signals. An internal audio amplifier and AM/FM detectors let one hear demodulated signals, using either the build-in speaker or headphone jace for signal identification and troubleshooting and in communications applications.

Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or Centronics interface via Opt. 09.

Front panel inputs/outputs are: RF INPUT N connector (50Ω, +20 dBm Max, 100 V DC blocking capacitor); and GEN N connector (50Ω, 0 to -48 dBm, Opt. 4 Tracking Generator generates a sweep frequency to enable the Spectrum Analyzer to make circuit response measurements, i.e. scalar network analysis).

Rear panel inputs/outputs are: J101 SMA connector (Female SMA installed for Opt. 15), J102 EXT TRIG BNC connector (10 kΩ, 35V (DC + peak AC)), J103 DB9 connector (Not RS-232 compatible. Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 GPIB connector (Digital Communication Port. IEEE Std 488 connector.) .

Key Specifications

{{Spec | Maximum Safe Input Power | +20 dBm (0.1W) continuous peak, ≤100 VDC
Frequency Range 10 kHz to 1.8 GHz
Frequency Span Range (plus 0 Hz and MAX: 180 MHz/div) 10 kHz/div to 100 MHz/div in 1, 2, 5 sequence
Resolution Bandwidth Range 6 dB bandwidth selections are 3 kHz, 30 kHz, 300 kHz, and 5 MHz ; Down to 300 Hz with Opt. 01
RF Input impedance 50 Ω
RF Attenuator Range 0 dB to 50 dB, 2 dB steps
Sensitivity -117 dBm at 3 kHz RBW, -129 dBm at 3 kHz RBW w/preamp
Reference Level Range -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV
Sweep Speed Range 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence
Triggering Modes Free Run, Internal, External, Line, TV Line, and TV Field
Displayed Average Noise −66 dBm to −100 dBm
Display Dynamic Range 80 dB
Dynamic Range ≥100 dBm
Internal Calibrator 100 MHz marker at -30 dBm
Included Accessories Operator’s Manual; Power Cord; Front Cover; Adapter 50 Ω N Male to BNC Female, Ω 75 to 50 Ω Minimum Loss Attenuator N Male to BNC Female
Weight Standard accessories: 11.25 kg (<25 lbs); Basic configuration: 9.5 kg (<21 lbs)
Power 90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 47 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)
Operating Atmospherics Temperatures: 0 °C to +50 °C; Humidity: MIL-Std-28800C class 5; Altitude: Up to 4.6 km (15,000 ft)

Options

  • Opt. 01: 300 Hz Resolution Bandwidth filter; Phase-lock with span/div ≤20 kHz
  • Opt. 02: Frequency Counter, 1 Hz or 1 kHz, menu selectable
  • Opt. 03: GPIB Interface (cannot be combined with Opt. 09)
  • Opt. 04: TG Tracking Generator, 100 kHz to 1.8 GHz (cannot be combined with Opt. 14)
  • Opt. 06: Battery Power Option (2704 Inverter and 2705 Battery Pack)
  • Opt. 08: RS-232(D) (cannot be combined with Opt. 03)
  • Opt. 09: Centronix interface (cannot be combined with Opt. 03)
  • Opt. 10: Video Monitor mode
  • Opt. 11: Non-volatile RAM storage for setups, displays, and user-definable key sequences
  • Opt. 14: Adds Resolution Bandwidths of 1 kHz, 10 kHz, 100 kHz, and 1 MHz (cannot be combined with Opt. 04)
  • Opt. 15: Tek 1405 TV Sideband Adapter interface installed at J101 as SMA female
  • Opt. 30: Rackmount
  • Opt. 33: Travel Line Package
  • Opt. 34: Portable to Rackmount Adapter.

See also the 2706 preselector and 2707 tracking generator.